Viet Nam
American
TKLD TECHNICAL SERVICE COMPANY LIMITED
HONEYWELL PROCESS SOLUTION CHANNEL PARTNER
Loading...
News
Danh sách tin tức
Home
News
Control Valve Servicings
30/10/2020 12:00:00
524
Danh mục Tin tức
Loading...
Tin tức mới
DVC6200 calibration services
Control Valve Servicings
Calibration Fisher DVC6200 Positioners
Troubleshooting of Siemens SIPART PS2 Valve Positioners
Configuring and Calibration the SIPART PS2 Valve Positioners
CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD
Địa chỉ: 432/16M2 Lê Đức Thọ, Phường 15, Quận Gò Vấp, Thành Phố Hồ Chí Minh
Hotline: +84-987 056 271
( Mr. Kiếm)
Email: info@tkld.com.vn
Thông tin thêm
On-Off valve maintenance & calibration services
Pressure switch calibration
Temperature switch calibration
Temperature transmitter calibration
Temperature gauge calibration
Pressure transmitter calibration
Pressure gauge and vaccum gauge calibration
Control valve maintenance & calibration services
Thống kê truy cập
:
0
:
484
:
2056
:
4112
:
23075
:
99999
Thiết Kế Website bởi P.A Việt Nam
{"default_contact":"Contact","default_notification":"Notification","default_redirect_click":"Click here","default_fullname":"Name","default_email":"Email","default_address":"Address","default_phone":"Phone","default_send":"Send","default_reset":"Làm lại","default_select_all":"All","default_captcha":"Enter Code","default_input_captcha":"Re-Enter Code","default_contact_send_success":"Bạn đã gởi liên hệ thành công","default_contact_send_false":"Bạn đã gởi liên hệ thất bại","default_back_page_home":"Quay về trang chủ","product_sort_name_asc":"Sắp xếp theo tên (A-Z)","product_sort_name_desc":"Sắp xếp theo tên (Z-A)","product_sort_price_asc":"Sắp xếp theo giá (Nhỏ -> Lớn)","product_sort_price_desc":"Sắp xếp theo giá (Lớn -> Nhỏ)","product_sort_price_sale_asc":"Sắp xếp theo khuyến mãi (Không -> Có)","product_sort_price_sale_desc":"Sắp xếp theo khuyến mãi (Có -> không)","key_option_product_discount":"Sản phẩm khuyến mãi","key_option_product_new":"Sản phẩm mới","key_option_product_special":"Sản phẩm đặt biệt","key_option_product_hot":"Sản phẩm Hot","key_option_news_new":"Tin mới","key_option_news_highlight":"Tin nổi bật","key_option_news_special":"Tin đặc biệt","key_option_news_hot":"Tin hot","key_option_classified_news_highlight":"Tin rao nổi bật","default_newsletter_thanks":"Cảm ơn bạn đã đăng ký trên hệ thống của chúng tôi","error_email_exists":"Email đã tồn tại trong hệ thống","error_email_not_exists":"Email không tồn tại trong hệ thống","error_email_invalid":"Địa chỉ email phải đúng cú pháp, ví dụ: info@tenmien.vn!","member_change_info_success":"Thông tin thay đổi thành công.","member_change_info_fail":"Thay đổi thông tin thất bại.","member_change_password_success":"Mật khẩu thay đổi thành công","member_change_password_fail":"Mật khẩu thay đổi thất bại","member_login_success":"Bạn đã đăng nhập thành công","member_register_success":"Đăng ký tài khoản thành công","member_register_fail":"Đăng ký tài khoản thất bại","member_send_password_new_mail_success":"Mật khẩu mới đã gửi về email đăng ký!","member_send_password_new_fail":"Lấy lại mật khẩu thất bại","error_account_not_found":"Không tìm thấy tài khoản trong hệ thống.","error_limit_login":"Bạn đã nhập sai vượt quá số lần quy định. Vui lòng đăng nhập lại sau:","error_username_required":"Bạn vui lòng nhập tên truy cập","error_username_not_exists":"Tên truy cập không tồn tại.","error_username_space":"Tên truy cập không được chứa khoảng trắng","error_username_exists":"Tên truy cập đã tồn tại","error_account_block":"Tài khoản đã bị khóa","error_password_not_exists":"Mật khẩu bạn nhập không chính xác.","error_password_required":"Bạn vui lòng nhập mật khẩu","error_password_not_regex":"Mật khẩu phải chứa ít nhất 6 ký tự. Bao gồm chữ in hoa, chữ thường và số.","error_password_old_required":"Nhập vào mật khẩu hiện tại của bạn","error_password_old_invalid":"Mật khẩu cũ không đúng","error_password_confirm_invalid":"Mật khẩu phải chứa ít nhất 6 ký tự. Bao gồm chữ in hoa, chữ thường và số.","error_register_is_login":"Bạn đã đăng nhập vào hệ thống. Vui lòng đăng xuất để thực hiện tính năng này","page_login":"Đăng nhập","error_fullname_required":"Bạn vui lòng nhập họ tên","error_fullname_max_length":"Họ tên Không vượt quá 55 ký tự","error_address_max_length":"Địa chỉ không vượt quá 150 ký tự","error_email_required":"Bạn vui lòng nhập email","error_content_required":"Bạn vui lòng nhập nội dung","error_content_max_length":"Nội dung gửi không được vượt quá 5000 ký tự","error_phone_required":"Bạn vui lòng nhập số điện thoại","error_phone_syntax":"Số điện thoại phải đủ 8 số hoặc lớn hơn, ví dụ: 19009477, 0967897890, 0286253737, ...","error_phone_exists":"Số điện thoại đã tồn tại trong hệ thống","error_captcha_required":"Bạn vui lòng nhập mã bảo vệ","error_captcha_invalid":"Mã bảo vệ không đúng","error_token_csrf_invalid":"Token không hợp lệ","time_invalid":"Thời gian không hợp lệ","forms_required":"Trường này là bắt buộc","forms_send_success":"Bạn đã gửi thông tin đăng ký thành công","forms_send_false":"Bạn đã gửi thông tin đăng ký thất bại","forms_undefined":"Không xác định được biểu mẫu","authentication_otp":"Xác thực OTP","authentication_otp_note":"Vui lòng kiểm tra điện thoại để lấy mã Xác thực.","error_limit_send_authentication_phone":"Quý khách đã đạt đến giới hạn xác thực số điện thoại.","error_time_resend_authentication_phone":"Chưa đến thời gian gửi lại.","send_code_otp_success":"Gửi mã OTP thành công","send_code_otp_error":"Gửi mã OTP thất bại","authentication_phone":"Xác thực số điện thoại","authentication_enter_code":"Nhập mã xác thực","authentication":"Xác thực","authentication_phone_re_send":"Gửi lại","authentication_phone_success":"Xác thực điện thoại thành công","verify_success":"Xác minh thành công","titile_authentication_phone_success":"Xác thực thành công","authentication_phone_error":"Xác thực điện thoại thất bại","warning_custom_no_authentication_phone":"Quý khách chưa xác thực số điện thoại","warning_phone_number_you_have_verified":"Số điện thoại của bạn đã xác minh","error_customer_access_page_here":"Quý khách chưa được truy cập trang này","skip_authenction":"Bỏ qua xác thực","error_enter_phone_invalid":"Khách hàng vui lòng nhập số điện thoại hợp lệ","error_info_invalid":"Thông tin không hợp lệ","error_code_verify_required":"Vui lòng nhập mã xác thực OTP","save_info_failed":"Lưu thông tin thất bại","save_info_success":"Lưu thông tin thành công","news":"Tin Tức","back_to_home":"Quay lại trang chủ","content_404":"Xin lỗi! Trang bạn đang tìm kiếm không tồn tại.","mail_welcome":"Xin chào: Anh\/Chị","best_regards":"Trân trọng","admin_website":"Ban quản trị","lost_password_subject":"Yêu cầu mật khẩu mới cho tài khoản!","lost_password_info":"Chúng tôi vừa nhận được yêu cầu khôi phục mật khẩu từ phía bạn. Vui lòng nhấn vào","lost_password_link":"đường dẫn","lost_password_active":"sau để kích hoạt mật khẩu mới.","news_password":"Mật khẩu mới:","account":"Tài khoản:","lost_password_contact":"Nếu Anh\/chị có bất kỳ câu hỏi nào, xin liên hệ với chúng tôi qua mail","onepay_cart":"Hệ thống sẽ chuyển qua cổng thanh toán OnePay.vn","product_payment_onepay":"Thanh toán OnePay","product_payment_onepay_atm":"OnePay cổng nội địa","product_payment_onepay_int":"OnePay cổng quốc tế","napas_cart":"Hệ thống sẽ chuyển qua cổng thanh toán Napas","product_payment_napas":"Thanh toán NaPas","product_payment_napas_atm":"Thanh toán NaPas nội địa","product_payment_napas_int":"Thanh toán NaPas quốc tế","product_payment_sacombank":"Thanh toán qua Sacombank","paypal_cart":"Hệ thống sẽ chuyển qua cổng thanh toán Paypal.com","product_payment_paypal":"Thanh toán PayPal","error_money_limit":"Số tiền lớn hơn mức cho phép của Paypal vui lòng chọn phương thức thanh toán khác","cart_paypal_express":"Hệ thống sẽ chuyển qua cổng thanh toán Paypal Express","vnpay_cart":"Hệ thống sẽ chuyển qua cổng thanh toán Vnpayment.vn","product_payment_vnpay":"Thanh toán VNPAY","zalopay_cart":"Hệ thống sẽ chuyển qua cổng thanh toán ZaloPay","product_payment_zalopay":"Thanh toán ZaloPay","product_payment_zalopay_app":"Thanh toán qua ví ZaloPay","product_payment_zalopay_atm":"Thanh toán ZaloPay cổng ATM","product_payment_zalopay_int":"Thanh toán ZaloPay cổng Visa\/MasterCard","error_zalopay_create_url_fail":"Tạo thanh toán qua ZaloPay thất bại. Vui lòng kiểm tra lại thông tin đơn hàng khi thanh toán.","zalopay_create_url_error":"ZaloPay tạo đơn hàng thất bại.","error_zalopay_payment_int":"Số tiền tối thiểu thanh toán qua cổng ZaloPay là 10.000đ","momo_cart":"Hệ thống sẽ chuyển qua cổng thanh toán MoMo","product_payment_momo":"Thanh toán qua ví MoMo","error_momo_create_url_fail":"Tạo thanh toán qua MoMo thất bại. Vui lòng kiểm tra lại thông tin đơn hàng khi thanh toán.","momo_create_url_error":"MoMo tạo đơn hàng thất bại.","error_momo_payment":"Số tiền tối thiểu thanh toán qua cổng MoMo là 1000đ","addon_video_relate":"Video liên quan","addon_video_empty":"Không có video thuộc chủ đề này","addon_video_error_notfound":"Không tìm thấy video trên hệ thống","cart_empty":"Bạn chưa chọn món hàng nào.","cart_payment":"Thanh Toán","cart_payment_method_online":"Thanh Toán trực tuyến","cart_order_now":"Đặt hàng nhanh","error_update_cart_fail":"Cập nhật giỏ hàng thất bại","error_update_cart_success":"Cập nhật giỏ hàng thành công","cart_add_success":"Thêm vào giỏ hàng thành công","cart_add_fail":"Thêm vào giỏ hàng thất bại","cart_add_fail_quantity":"Số lượng sản phẩm mua vượt quá số lượng có","error_login_add_cart":"Quý khách vui lòng đăng nhập để đặt hàng","confirm_delete_cart":"Bạn chắc chắn muốn xóa sản phẩm này khỏi giỏ hàng","cart_delete_success":"Xóa giỏ hàng thành công","cart_delete_fail":"Xóa giỏ hàng thất bại","cart_nganluong":"Hệ thống sẽ chuyển qua cổng thanh toán NganLuong.vn","cart_baokim":"Hệ thống sẽ chuyển qua cổng thanh toán BaoKim.vn","order_success":"Đặt hàng thành công","cart_order_success":"Thông tin đặt hàng thành công","cart_order_thank":"Xin cảm ơn quý khách đã đặt hàng trên hệ thống của chúng tôi.","cart_order_success_thank_customer":"Đặt hàng thành công, xin cảm ơn quý khách đã đặt hàng trên hệ thống của chúng tôi.","cart_note":"Ghi chú","cart_total_price":"Tổng tiền","cart_order_info":"Thông tin đơn hàng","cart_price_detail":"Chi tiết giá","cart_order_button":"Sửa","cart_payment_transportation":"Phương thức vận chuyển","form_of_delivery":"Hình thức giao hàng","cart_payment_transport_to":"Vận chuyển đến","cart_payment_select_provinces":"--- Chọn tỉnh\/thành ---","cart_payment_select_state":"--- Chọn bang ---","cart_payment_select_region":"--- Chọn Khu vực ---","cart_payment_select_district":"--- Chọn quận\/huyện ---","cart_payment_select_ward":"--- Chọn phường\/xã ---","cart_payment_city_name":"Nhập thành phố","cart_payment_postal_code":"Nhập Zip\/Postal code","cart_payment_select_shipping_method":"Chọn hãng\/phương thức giao hàng","cart_payment_transport_select":"Chọn","cart_payment_shipping_carrier":"Hãng vận chuyển","cart_payment_estimated_time":"Thời gian dự kiến","cart_payment_transport_fee":"Phí vận chuyển","cart_payment_transport_service":"Dịch vụ vận chuyển","cart_payment_cod_fee":"Phí thu hàng hộ","cart_payment_total_shipping_cost":"Tổng tiền vận chuyển","cart_payment_not_transport":"Bạn có muốn nhận hàng trực tiếp tại shop ?","shipping_fast":"Giao hàng nhanh","shipping_default":"Giao hàng mặc định","shipping_other_form":"Hình thức khác","shipping_other_form_desc":"Shop liên hệ sau khi đặt hàng thành công","info_extend_payment":"Thông tin thêm","cart_customer_info":"Thông tin khách hàng","cart_buyer_info":"Người mua hàng","cart_receive_info":"Người nhận hàng","cart_use_buyer_info":"Sử dụng thông tin người mua hàng","view_cart":"Giỏ hàng","discount_shipping_note":"Giảm giá cho phí vận chuyển","address_received_product":"Địa chỉ nhận hàng","product_payment_at_the_receive":"Thanh toán khi nhận hàng","product_payment_at_the_company":"Thanh toán tại công ty","product_payment_nganluong":"Thanh toán NganLuong.vn","product_payment_baokim":"Thanh toán BaoKim.vn","product_payment_transfer":"Thanh toán chuyển khoản","product_payment_transfer_qr":"Chuyển khoản qua QR","please_warning_enter_address_shipping":"Vui lòng chọn địa chỉ giao hàng","warning_empty_province_to_shipping":"Hiện tại không có hình thức vận chuyển phù hợp","message_not_used_method_payment":"* Chúng tôi sẽ liên hệ quý khách khi nhận được đơn hàng. Hình thức thanh toán sẽ được chúng tôi thông báo đến quý khách sớm.","product_compare_limit":"Danh sách so sánh đã đạt giới hạn cho phép (10 sản phẩm)","address_store_payment":"Địa chỉ cửa hàng","shipping_status_not_delivery":"Chưa giao hàng","status_shipping_delivered":"Đã giao hàng","status_shipping_cancel_delivery":"Hủy giao hàng","error_payment_method_required":"Xin vui lòng chọn hình thức thanh toán cho đơn hàng này","error_payment_method_fail":"Hình thức thanh toán này chưa cập nhật. Vui lòng chọn hình thức thanh toán khác","error_payment_fail":"Đã có lỗi trong quá trình thanh toán","error_payment_address_required":"Xin vui lòng nhập vào địa chỉ liên lạc của bạn!","error_payment_receive_address_required":"Xin vui lòng nhập vào địa chỉ người nhận!","error_payment_fullname_required":"Xin vui lòng nhập vào họ tên người liên hệ","error_payment_receive_fullname_required":"Xin vui lòng nhập vào họ tên người nhận","error_payment_email_required":"Hãy nhập vào địa chỉ Email mà bạn đang sử dụng","error_payment_transport_not_exists":"Không tồn tại phương thức vận chuyển này","error_cart_product_not_found":"Không tìm thấy sản phẩm giỏ hàng","error_value_must_not_be_less_than_1":"Giá trị không được nhỏ hơn 1","error_transport_method_empty":"Vui lòng chọn phương thức vận chuyển cho đơn hàng này","error_payment_total_0":"Không thể chọn phương thức thanh toán online khi giá trị đơn hàng là 0đ","error_payment_warning_select":"Không có phương thức thanh toán trực tuyến phù hợp với đơn hàng hiện tại","error_payment_province_select":"Xin vui lòng chọn tỉnh\/thành","error_payment_district_select":"Xin vui lòng chọn quận\/huyện","error_payment_ward_select":"Xin vui lòng chọn phường\/xã","error_shipping_warning_select":"Không có phương thức vận chuyển phù hợp với địa chỉ này","error_payment_shipping_rate_select":"Xin vui lòng chọn phương thức vận chuyển","error_payment_shipping_rate_not_valid":"Phương thức vận chuyển không hợp lệ","error_payment_city_name_required":"Xin vui lòng nhập vào tên thành phố","error_payment_postal_code_required":"Xin vui lòng nhập mã bưu chính","error_confirm_terms_invalid":"Bạn phải đồng ý với điều khoản trước khi thanh toán","coupon_used":"Sử dụng Coupon","point_used":"Sử dụng điểm thưởng","point_current_me":"Điểm thưởng hiện tại","voucher_used":"Sử dụng Voucher","coupon_input":"Nhập mã Coupon","voucher_input":"Nhập mã Voucher","coupon_button_apply":"Áp dụng","coupon_label":"Giảm giá Coupon","voucher_label":"Giảm giá Voucher","apply_code_coupon_success":"Áp dụng mã coupon thành công","apply_code_voucher_success":"Áp dụng mã voucher thành công","error_coupon_required":"Vui lòng nhập mã Coupon để sử dụng","error_voucher_required":"Vui lòng nhập mã Voucher để sử dụng","error_coupon_not_exists":"Mã Coupon không tồn tại!","error_coupon_not_accept":"Mã Coupon không hợp lệ!","error_coupon_not_used":"Mã Coupon đã hết lượt sử dụng!","error_coupon_total_product":"Giá trị đơn hàng tối thiểu không hợp lệ!","error_voucher_not_exists":"Mã Voucher không tồn tại!","error_voucher_not_accept":"Mã Voucher không hợp lệ!","error_voucher_not_used":"Mã Voucher đã hết lượt sử dụng!","error_coupon_apply_promotion":"Mã này không áp dụng đồng thời cùng chương trình khuyến mãi","show_more":"Xem thêm","show_less":"Thu gọn","product_in_of_stock":"Còn hàng","product_out_of_stock":"Hết hàng","product_viewed_confrim_remove":"Bạn chắc chắn muốn xóa sản phẩm này khỏi danh sách đã xem","product_viewed_confrim_remove_success":"Xóa sản phẩm khỏi danh sách đã xem thành công","product_viewed_confrim_remove_fail":"Xóa sản phẩm khỏi danh sách đã xem thất bại","product_compare_add_success":"Sản phẩm đã được thêm vào so sánh","product_compare_add_fail":"Thêm sản phẩm vào so sánh thất bại","product_compare_confirm_delete":"Bạn chắc chắn muốn xóa sản phẩm này khỏi danh sách so sánh","product_compare_confirm_delete_all":"Bạn chắc chắn muốn xóa tất cả sản phẩm này khỏi danh sách so sánh","product_compare_delete_success":"Xóa sản phẩm khỏi danh sách so sánh thành công","product_compare_delete_success_fail":"Xóa sản phẩm khỏi danh sách so sánh thất bại","add_favorite_success":"Thêm vào danh sách yêu thích thành công","add_favorite_fail":"Thêm vào danh sách yêu thích thất bại","product_favorite_confrim_remove":"Bạn chắc chắn muốn xóa sản phẩm này khỏi danh sách yêu thích","remove_favorite_success":"Xóa sản phẩm khỏi danh sách yêu thích thành công","remove_favorite_fail":"Xóa sản phẩm khỏi danh sách yêu thích thất bại","error_login_required":"Đăng nhập để thực hiện thao tác này","error_product_exists":"Sản phẩm đã tồn tại","error_product_not_found":"Không tìm thấy sản phẩm trên hệ thống","product_content_expand":"Xem thêm nội dung","product_content_collapse":"Ẩn bớt nội dung","title_order":"Đơn hàng","shipping_to":"Vận chuyển tới","promotion":"Khuyến mãi","order_expires_view":"Đơn hàng hết hạn xem","order_into_money":"Thành tiền","order_price_temporary":"Tạm tính","order_total_product":"Tổng tiền hàng","order_vat":"VAT","payment_method":"Hình thức thanh toán","delivery_method":"Hình thức giao hàng","error_order_not_found":"Không tìm thấy đơn hàng trong hệ thống. Bạn vui lòng làm mới lại website","error_content_lenght_must_be_than_10":"Nội dung phải lớn hơn 9 ký tự","error_add_member_success":"Gửi câu hỏi thành công.","error_add_member_fail":"Gửi câu hỏi thất bại.","code_product":"Mã sản phẫm","date_order":"Ngày giờ đặt hàng","receive_at_the_shop":"Đến nhận hàng trực tiếp tại cửa hàng","info_store_address":"Thông tin cửa hàng","delivery_to_your_place":"Giao hàng tận nơi","cart_code":"Mã đơn hàng","note_send_mail_order":"Nếu Anh\/chị có bất kỳ câu hỏi nào, xin liên hệ với chúng tôi qua mail","admin_shop":"Ban quản trị cửa hàng","transfer_information":"Thông tin chuyển khoản","order_shipping_to":"Đơn hàng sẽ được giao đến","notify_order_receive_and_contact_customer":"Đơn hàng của Anh\/Chị đã được tiếp nhận, chúng tôi sẽ nhanh chóng liên hệ với Anh\/Chị.","cart_discount":"Giảm giá","add_cart":"Thêm vào giỏ hàng","buy_more":"Mua thêm","send_product_reviews_success":"Gửi đánh giá sản phẩm thành công","send_product_reviews_error":"Gửi đánh giá sản phẩm thất bại","empty_product_id_error":"Sản phẩm rỗng","error_customer_write_review_consecutive":"Quý khách vui lòng đánh giá sau 5 phút","used_point":"Sử dụng điểm thưởng","look_up_order":"Tra cứu đơn hàng","status_order":"Trạng thái đơn hàng","no_exits_order":"Không tồn tại đơn hàng","result_look_up":"Kết quả","look_up":"Tra cứu","product":"Sản phẩm","service":"Dịch vụ","copy_content_success":"Sao chép thành công","subject_title_send_mail":"Thông tin đặt hàng - MĐH","from":"từ","payment_method_unknown":"Không xác định","status_order_new":"Đơn hàng mới","status_order_accepted_processing":"Đang xử lý","status_order_pending":"Chờ xuất hàng","status_order_out_stock":"Xuất hàng","status_order_completed":"Hoàn thành","status_order_cancel":"Hủy đơn hàng","status_paid":"Đã thanh toán","status_unpaid":"Chờ thanh toán","method":"Phương thức","confirm":"Xác nhận","bank":"Ngân hàng","account_no":"Số tài khoản","content":"Nội dung","number_money":"Số tiền","summary_order":"Tóm tắt đơn hàng","selected_country":"Quốc gia","error_country_empty":"Quốc gia không thể trống","default":"Mặc định","product_payment_qr":"Chuyển khoản qua QR Code","order_not_found":"Không tìm thấy đơn hàng","cart_payment_success":"Thanh toán thành công","cart_payment_fail":"Thanh toán thất bại","cart_payment_welcome":"Xin chào: Anh\/Chị","cart_payment_thank":"Cảm ơn Anh\/Chị đã đặt hàng trên website của chúng tôi.","cart_payment_noti_success":"Giao dịch thanh toán đơn hàng của Anh\/Chị đã thành công. Mã đơn hàng của Anh\/Chị là:","cart_payment_order_fail":"Số đơn hàng của Anh\/Chị là:","cart_payment_order_cus_noti":"Giao dịch của Anh\/Chị","cart_payment_order_status":"không thành công","cart_payment_phone":"Điện thoại hỗ trợ:","cart_payment_email":"Email hỗ trợ:","cart_payment_back_home":"Trở về trang chủ trong","cart_payment_contact":"Vui lòng kiểm tra lại thông tin thanh toán hoặc liên hệ với chúng tôi để biết thêm thông tin chi tiết.","cart_error_no":"Mã lỗi","result_payment_online":"Kết quả thanh toán online đơn hàng","you_have_just_made_online_payment_transaction_for_your_order":"Anh\/Chị vừa thực hiện giao dịch thanh toán online cho đơn hàng:","status_transaction":"Trạng thái giao dịch:","if_you_any_question_please_contact_us_via_mail":"Nếu Anh\/chị có bất kỳ câu hỏi nào, vui lòng liên hệ với chúng tôi qua mail"}
{"company_logo":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/TKLD_Logo.jpg?t=1753021068","company_name":"TKLD TECHNICAL SERVICE COMPANY LIMITED","company_email":"info@tkld.com.vn","company_phone":"+84-987 056 271 (Mr. Kiem)","company_address":"432\/16M2 Le Duc Tho Street, Ward 15, Go Vap District, Ho Chi Minh City, Viet Nam 700000","company_fax":"","date_now":1776430688,"company_tags":["CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD","TKLD","CÔNG TY TKLD","TKLD TECHNICAL","Dịch vụ sửa chữa van bi","Dịch vụ sửa chữa van điều khiển","Dịch vụ sửa chữa van","tkld","tkld technical","control valve overhaul","control valve maintenance services","control valve repair","Honeywell Instrument","Honeywell Viet Nam","Honeywell Partner","Honeywell process instrument","Honeywell Field Instrument","Honeywell STT850 temperature transmitter","Honeywell STT750 temperature transmitter","Honeywell ST700 Pressure Transmitters","Honeywell ST800 Pressure Transmitters","ST700 Diaphragm Seal Pressure Transmitters","ST800 Diaphragm Seal Pressure Transmitters","Honeywell Distributor","Honeywell Partner","Honeywell Process solution","HONEYWELL PROCESS SOLUTION CHANNEL PARTNER","Smart Pressure transmitter","Smart Hart Pressure transmitter","Rosemount Pressure Transmitter","Yokogawa Pressure transmitter","Pressure Transmitters","Smart Pressure Transmitters","Pressure Transmitter 4-20mA","Pressure Transmitter 4-20mA Hart","Pressure Transmitter Foundation Fieldbus","Differential Pressure Transmitters","Differential Smart Pressure Transmitters","Differential Pressure Transmitter 4-20mA","Differential Pressure Transmitter 4-20mA Hart","Differential Pressure Transmitter Foundation Fieldbus","Gauge Pressure Transmitters","Gauge Smart Pressure Transmitters","Gauge Pressure Transmitter 4-20mA","Gauge Pressure Transmitter 4-20mA Hart","Gauge Pressure Transmitter Foundation Fieldbus","Diaphragm Seal Pressure Transmitters","Diaphragm Seal Smart Pressure Transmitters","Diaphragm Seal Pressure Transmitter 4-20mA","Diaphragm Seal Pressure Transmitter 4-20mA Hart","Diaphragm Seal Pressure Transmitter Foundation Fieldbus","Remote Diaphragm Pressure Transmitters","Remote Diaphragm Smart Pressure Transmitters","Remote Diaphragm Pressure Transmitter 4-20mA","Remote Diaphragm Pressure Transmitter 4-20mA Hart","Remote Diaphragm Pressure Transmitter Foundation Fieldbus","Thiết bị chuyển đổi áp suất","Thiết bị chuyển đổi áp suất 4-20mA Hart","Thiết bị chuyển đổi áp suất FF","Thiết bị chuyển đổi áp suất Foundation Fieldbus","Thiết bị chuyển đổi tín hiệu áp suất","Thiết bị chuyển đổi tín hiệu áp suất 4-20mA Hart","Thiết bị chuyển đổi tín hiệu áp suất FF","Thiết bị chuyển đổi tín hiệu áp suất Foundation Fieldbus","Bộ chuyển đổi tín hiệu áp suất","Bộ chuyển đổi tín hiệu áp suất 4-20mA","Bộ chuyển đổi tín hiệu áp suất 4-20mA Hart","Cảm biến đo áp suất","Cảm biến đo áp suất hơi","Cảm biến đo áp suất hơi bão hoà","Cảm biến đo áp suất hơi quá nhiệt","Cảm biến đo áp suất bồn","Cảm biến đo áp suất nước","Cảm biến đo áp suất bơm","Smart Pressure transmitter","Smart Hart Pressure transmitter","Rosemount Pressure Transmitter","Yokogawa Pressure transmitter","Pressure Transmitters","Smart Pressure Transmitters","Pressure Transmitter 4-20mA","Pressure Transmitter 4-20mA Hart","Pressure Transmitter Foundation Fieldbus","Differential Pressure Transmitters","Differential Smart Pressure Transmitters","Differential Pressure Transmitter 4-20mA","Differential Pressure Transmitter 4-20mA Hart","Differential Pressure Transmitter Foundation Fieldbus","Gauge Pressure Transmitters","Gauge Smart Pressure Transmitters","Gauge Pressure Transmitter 4-20mA","Gauge Pressure Transmitter 4-20mA Hart","Gauge Pressure Transmitter Foundation Fieldbus","Diaphragm Seal Pressure Transmitters","Diaphragm Seal Smart Pressure Transmitters","Diaphragm Seal Pressure Transmitter 4-20mA","Diaphragm Seal Pressure Transmitter 4-20mA Hart","Diaphragm Seal Pressure Transmitter Foundation Fieldbus","Remote Diaphragm Pressure Transmitters","Remote Diaphragm Smart Pressure Transmitters","Remote Diaphragm Pressure Transmitter 4-20mA","Remote Diaphragm Pressure Transmitter 4-20mA Hart","Remote Diaphragm Pressure Transmitter Foundation Fieldbus","STF724 Flange Mount Pressure Transmitters","SmartLine STF700","STF724 Pressure transmitter","STF725 Pressure transmitter","STF732 Pressure transmitter","STF735 Pressure transmitter","STF72F Pressure transmitter","STF73F Pressure transmitter","Honeywell STF724 Pressure transmitter","Honeywell STF725 Pressure transmitter","Honeywell STF732 Pressure transmitter","Honeywell STF735 Pressure transmitter","Honeywell STF72F Pressure transmitter","Honeywell STF73F Pressure transmitter","Honeywell Pressure transmitter","Honeywell STF700 Pressure transmitter","The ST700 Flange Mount Pressure Transmitters","Flange Mount Transmitters SmartLine STF700","Flange Mount Transmitters Honeywell STF700","Honeywell Pressure Transmitter","ST700 SmartLine Pressure Transmitter","Honeywell The ST700 transmitter","Cảm biến áp suất ST700","Cảm biến đo áp suất ST700","Cảm biến áp suất Honeywell ST700","SmartLine STF700 Flange Mount Transmitter","Honeywell STF700 SmartLine Flange Mounted Level Transmitter Cảm biến áp suất STF700","Cảm biến áp suất Honeywell STF700","Cảm biến áp suất Honeywell","Cảm biến áp suất Honeywell STF724","Cảm biến áp suất Honeywell STF725","Cảm biến áp suất Honeywell STF732","Cảm biến áp suất Honeywell STF735","Cảm biến áp suất Honeywell STF72F","Cảm biến áp suất Honeywell STF73F","Honeywell SmartLine STF700","Honeywell Viet Nam","Đại lý honeywell","Honeywell Viet Nam Partner","Thiết bị đo lường Honeywell Vietnam","Thiết bị đo lường Honeywell STF700","Thiết bị đo áp suất Honeywell STG700"],"search_keyword":"Control Valve Servicing","facebook_comment":"https:\/\/www.tkld-technical.com.vn\/tin-tuc.html","breadscrumb":[{"url":"https:\/\/www.tkld-technical.com.vn","name":"Home","icon":"","active":false},{"url":"javascript:void(0)","name":"News","icon":"","active":true}],"list_products_tmp":[],"list_section":[{"id":271234,"name":"SECTION-11889","seo_name":"#w30s-section-271234","url":"#w30s-section-271234"},{"id":271232,"name":"SECTION-11932","seo_name":"#w30s-section-271232","url":"#w30s-section-271232"},{"id":271242,"name":"SECTION-12727","seo_name":"#w30s-section-271242","url":"#w30s-section-271242"},{"id":271230,"name":"SECTION-11890","seo_name":"#w30s-section-271230","url":"#w30s-section-271230"}],"category_image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/TKLD_Logo.jpg?t=1753021068","type_page":6,"id_page":141298,"widget_10130907":{"content_data":[{"id":40523,"title":"Viet Nam","code":"vn","is_expires":false,"is_active":1},{"id":40524,"title":"American","code":"us","is_expires":false,"is_active":0}]},"widget_11824762":{"content_data":{"content":"<p><span style=\"font-size:20px\"><span style=\"font-family:Times New Roman,Times,serif\"><span style=\"color:#e74c3c\">HONEYWELL PROCESS SOLUTION CHANNEL PARTNER<\/span><\/span><\/span><\/p>\n"}},"widget_6796117":{"content_data":[]},"widget_6796119":{"content_data":{"content":"<span class=\"w30s-content\"><br><\/span>"}},"widget_6719870":{"content_data":[{"id":664386,"name":"Control Valve Servicings","desc":"","content":"<p><strong><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">CONTROL VALVE SERVICING<\/span><\/span><\/strong><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Specialist <b>Control Valve Servicing<\/b> Company for all makes\/brands – servicing, overhaul, supply of spare parts, testing and calibration<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Test standards used : ANSI B16.104\/VDI\/VDE 2174\/ FCI70-2 (Seat leak & Bubble test\/ API 598\/6D<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overhaul, testing and commissioning of Level Instruments<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Supply of Diagnostic Instruments<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Full Diagnostics monitoring and testing services<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valvelink program – for quick assembles and deliveries<\/span><\/span><\/li>\n<\/ul>\n\n<p><img src=\"\/datafiles\/40367\/upload\/images\/TKLD%20Control%20valve%20servicing.jpeg\" style=\"width: 800px; height: 1067px;\" \/><\/p>\n","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/Control%20Valve%20Services\/Masoneilan%2020%20inch%20Anti%20surge%20valve.JPG","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/Control%20Valve%20Services\/Masoneilan%2020%20inch%20Anti%20surge%20valve.JPG","tags":["Control Valve Servicing","Ball Valve Hydrostatic test","Ball Valve Leak test","Bảo dưỡng sửa chữa van điều khiển","bảo dưỡng thiết bị","Bảo dưỡng van","bảo trì","bảo trì van điều khiển khí nén","Butterfly Control Valve Maintenance Services","Butterfly Valve Ball Valve Hydrostatic test","Check Valve Hydrostatic test","Check Valve Leak test","Control Valve Cablibration","Control Valve Calibration","Control valve calibration service","Control Valve Calibration Services","Control valve commissioning and testing","Control Valve Hydrostatic test","Control Valve Inspection","Control Valve Inspection and Calibration","Control valve inspection and testing","Control Valve Inspection Service","Control Valve Maintenance and Testing","Control Valve Maintenance Services","Control valve maintenance training","Control Valve Overhaul","Control valve overhaul training","Control valve pre-commissioning","Control Valve Repair","Control Valve Repair Serivce","Control Valve Seat Leak test","Control Valve Services","Control Valve Testing","Control Valve Testing Service","Dịch vụ bảo dưỡng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Cầu","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Mặt Bích Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van an toàn","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van Cổng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điện","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điều khiển","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van một chiều","Dịch vụ bảo trì sửa chữa van công nghiệp","Dịch vụ cân chỉnh van điều khiển","Dịch vụ đào tạo bảo dưỡng sửa chữa van điều khiển","Dịch vụ đào tạo bảo dưỡng van","Dịch vụ đào tạo hiệu chỉnh van điều khiển","Dịch vụ đào tạo loop check hệ thống điện","Dịch vụ đào tạo loop check hệ thống điều khiển","Dịch vụ đào tạo loop check van điều khiển","Dịch vụ đào tạo loop test hệ thống điện","Dịch vụ đào tạo loop test hệ thống điều khiển","Dịch vụ đào tạo loop test hệ thống điiều khiển","Dịch vụ đào tạo loop test van điều khiển","Dịch vụ đào tạo sửa chữa van","Dịch vụ đào tạo sửa chữa van điều khiển","Dịch vụ hiệu chuẩn van điều khiển","Dịch vụ hydrotest van","Dịch vụ mài rà mặt làm kín van","Dịch vụ mài rà van cổng","Dịch vụ mài rà van dao","Dịch vụ sửa chữa bảo dưỡng van điện","Dịch vụ sửa chữa bảo dưỡng van tay","Dịch vụ sửa chữa bảo dưỡng van thủy lực","Dịch vụ sửa chữa bộ điều khiển van","Dịch Vụ sửa chữa mặt làm kín van","DỊCH VỤ SỬA CHỮA TẤT CẢ CÁC LOẠI VAN","Dịch vụ sửa chữa van","Dịch vụ sửa chữa van bi","Dịch vụ sửa chữa van bướm","Dịch vụ sửa chữa van công nghiệp","Dịch vụ sửa chữa van một chiều","Dịch vụ thử áp đường ống","Dịch vụ thử áp hệ thống","Dịch vụ thử áp van điều khiển","Dịch vụ thử rò rỉ van điều khiển","Dịch vụ thử rò rỉ van tay","Dịch vụ thử rò van điều khiển","Dịch vụ thử thuỷ lực thân van","Dịch vụ thử thuỷ lực van điều khiển","Dịch vụ thử thuỷ lực van tay","Fucntion test control valves","Gate Valve Hydrostatic test","Gate Valve Leak test","Gate Valve Repair Serivce","Gia công mặt làm kín van","Globe Control Valve Maintenance Services","Globe Valve Hydrostatic test","Globe Valve Leak test","Hiệu chỉnh van điều khiển","Hiệu chuẩn van điều khiển","Hydrostatic test as per API 598","Hydrostatic test as per API 6D","lắp đặt van điều khiển khí nén","Manual valve hydrostatic test","Manual valve leak test","Manual Valve Repair Serivce","Manual valve testing","On-Off Valve Hydrostatic test","On-Off Valve Repair Serivce","On-Off Valve Seat Leak test","Overhaul Control Valves","phục hồi các loại van","Phun phủ kim loại","Phun phủ kim loại cho bề mặt của các chi tiết cơ khí","Phun phủ kim loại phục hồi bề mặt của các chi tiết cơ khí","Pneumatic actuator overhaul","Pneumatic actuator testing","Positioner repair","Pressure Safety Valve Calibration Service","Pressure Safety Valve Maintenance","Pressure Safety Valve Overhaul","Pressure Safety Valve Repair Serivce","Pressure Safety Valve Testing","Pressure Safety Valve Verification Service","PSV repair","PSV testing","PSV Verification","Repair control valves","Rotork actuator maintenance service","Samson control valves","Seat Leak test as per API 598","Seat Leak test as per FCI 70-2","Seat Leakage Test as per API 527","Sửa chữa","Sửa chữa kiểm định van an toàn","Sửa chữa mặt làm kín mặt bích","Sửa chữa mặt làm kín van","Sửa chữa van","Sửa chữa van an toàn","Sửa chữa van điều khiển","Sữa chữa van điều khiển Fisher","Sữa chữa van điều khiển Masoneilan","Sữa chữa van KOMOTO","Sửa chữa van KOSO","Sửa chữa van tay","thử nghiệm van điều khiển","Valve calibration Service","valve raise face lapping","valve raise face repair","Valve Services","Valve Surface lapping"],"count_view":524,"seo_name":"control-valve-servicings","date_update":1604034000,"date_created_format":1729944505,"meta_title":"Control Valve Servicing","meta_desc":"Control Valve Servicing","meta_keyword":"Control Valve Servicing,Ball Valve Hydrostatic test, Ball Valve Leak test, Bảo dưỡng sửa chữa van điều khiển, bảo dưỡng thiết bị, Bảo dưỡng van, bảo trì, bảo trì van điều khiển khí nén, Butterfly Control Valve Maintenance Services, Butterfly Valve Ball Va","qr_code":"https:\/\/www.tkld-technical.com.vn\/control-valve-servicings.html"}],"content_pagging":{"firstCurrentItem":1,"lastCurrentItem":1,"total":1,"limit":9,"currentPage":1,"total_page":1,"pages":[{"active":false,"disable":true,"type":"first","page":1,"url":"javascript:void(0)"},{"active":false,"disable":true,"type":"prev","page":1,"url":"javascript:void(0)"},{"active":true,"disable":false,"type":"page","page":1,"url":"javascript:void(0)"},{"active":false,"disable":false,"type":"next","page":1,"url":"javascript:void(0)"},{"active":false,"disable":false,"type":"last","page":1,"url":"javascript:void(0)"}]}},"widget_6719883":{"content_data":{"content":""}},"widget_6719884":{"content_data":{"content":"Danh sách tin tức"}},"widget_6719894":{"content_data":[{"id":664387,"name":"DVC6200 calibration services","desc":"","content":"<h2><strong><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">DVC6200 calibration services<\/span><\/span><\/strong><\/h2>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">On receiving a DVC6200 the instrument mode is “In Service.” Follow these simple steps to get your device up and running.<\/span><\/span><\/p>\n\n<ol>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Hook up a HART<sup>® <\/sup>communicator to the DVC6200 in parallel with a 4-20 mA loop across the “loop” terminals<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Apply a 4 mA signal to the DVC and power up the HART communicator<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">First, put the instrument in “not in service” mode. Do this by entering the menu ‘configure’, then ‘detailed setup’, then ‘mode and protection’, then ‘instrument mode’<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Choose “not in service” and press enter<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Hit the home key to return to the main menu<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Now enter ‘configure’, then ‘guided setup’, then ‘setup wizard’<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Entering ‘setup wizard’ will start you through configuration prompts asking for information about the actuator and valve you are working with<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Enter the actuator manufacturer, type, size, and supply pressure requirements as requested by the communicator<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When asked, go ahead and send the factory defaults to begin with (fine tuning can be adjusted later)<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">After completing the setup wizard portion, the communicator will prompt you to start the auto-travel calibration portion<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When asked for adjustment method for output bias choose manual<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The communicator will automatically stroke the valve to 100% travel and 0% travel and adjust the output bias<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When it asks for 50%, adjust the mA input to 12 mA and proceed with the remainder of the auto-travel calibration procedure<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Afterwards the communicator will prompt you to return it to “in service” mode; do so<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Stroke the valve completely and make sure your valve opens linear to your 4-20 mA input signal<\/span><\/span><\/li>\n<\/ol>\n\n<p><img src=\"\/datafiles\/40367\/upload\/images\/TKLD%20DVC6200%20Calibration%20.jpg\" style=\"width: 800px; height: 1067px;\" \/><\/p>\n\n<p> <\/p>\n","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/DAM%20CA%20MAU%202023\/ca%20mau%202023-2.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/DAM%20CA%20MAU%202023\/ca%20mau%202023-2.jpg","tags":["DVC6200 calibration service","Ball Valve Hydrostatic test","Ball Valve Leak test","Bảo dưỡng sửa chữa van điều khiển","bảo dưỡng thiết bị","Bảo dưỡng van","bảo trì","bảo trì van điều khiển khí nén","Butterfly Control Valve Maintenance Services","Butterfly Valve Ball Valve Hydrostatic test","Check Valve Hydrostatic test","Check Valve Leak test","Control Valve Cablibration","Control Valve Calibration","Control valve calibration service","Control Valve Calibration Services","Control valve commissioning and testing","Control Valve Hydrostatic test","Control Valve Inspection","Control Valve Inspection and Calibration","Control valve inspection and testing","Control Valve Inspection Service","Control Valve Maintenance and Testing","Control Valve Maintenance Services","Control valve maintenance training","Control Valve Overhaul","Control valve overhaul training","Control valve pre-commissioning","Control Valve Repair","Control Valve Repair Serivce","Control Valve Seat Leak test","Control Valve Services","Control Valve Testing","Control Valve Testing Service","Dịch vụ bảo dưỡng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Cầu","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Mặt Bích Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van an toàn","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van Cổng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điện","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điều khiển","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van một chiều","Dịch vụ bảo trì sửa chữa van công nghiệp","Dịch vụ cân chỉnh van điều khiển","Dịch vụ đào tạo bảo dưỡng sửa chữa van điều khiển","Dịch vụ đào tạo bảo dưỡng van","Dịch vụ đào tạo hiệu chỉnh van điều khiển","Dịch vụ đào tạo loop check hệ thống điện","Dịch vụ đào tạo loop check hệ thống điều khiển","Dịch vụ đào tạo loop check van điều khiển","Dịch vụ đào tạo loop test hệ thống điện","Dịch vụ đào tạo loop test hệ thống điều khiển","Dịch vụ đào tạo loop test hệ thống điiều khiển","Dịch vụ đào tạo loop test van điều khiển","Dịch vụ đào tạo sửa chữa van","Dịch vụ đào tạo sửa chữa van điều khiển","Dịch vụ hiệu chuẩn van điều khiển","Dịch vụ hydrotest van","Dịch vụ mài rà mặt làm kín van","Dịch vụ mài rà van cổng","Dịch vụ mài rà van dao","Dịch vụ sửa chữa bảo dưỡng van điện","Dịch vụ sửa chữa bảo dưỡng van tay","Dịch vụ sửa chữa bảo dưỡng van thủy lực","Dịch vụ sửa chữa bộ điều khiển van","Dịch Vụ sửa chữa mặt làm kín van","DỊCH VỤ SỬA CHỮA TẤT CẢ CÁC LOẠI VAN","Dịch vụ sửa chữa van","Dịch vụ sửa chữa van bi","Dịch vụ sửa chữa van bướm","Dịch vụ sửa chữa van công nghiệp","Dịch vụ sửa chữa van một chiều","Dịch vụ thử áp đường ống","Dịch vụ thử áp hệ thống","Dịch vụ thử áp van điều khiển","Dịch vụ thử rò rỉ van điều khiển","Dịch vụ thử rò rỉ van tay","Dịch vụ thử rò van điều khiển","Dịch vụ thử thuỷ lực thân van","Dịch vụ thử thuỷ lực van điều khiển","Dịch vụ thử thuỷ lực van tay","Fucntion test control valves","Gate Valve Hydrostatic test","Gate Valve Leak test","Gate Valve Repair Serivce","Gia công mặt làm kín van","Globe Control Valve Maintenance Services","Globe Valve Hydrostatic test","Globe Valve Leak test","Hiệu chỉnh van điều khiển","Hiệu chuẩn van điều khiển","Hydrostatic test as per API 598","Hydrostatic test as per API 6D","lắp đặt van điều khiển khí nén","Manual valve hydrostatic test","Manual valve leak test","Manual Valve Repair Serivce","Manual valve testing","On-Off Valve Hydrostatic test","On-Off Valve Repair Serivce","On-Off Valve Seat Leak test","Overhaul Control Valves","phục hồi các loại van","Phun phủ kim loại","Phun phủ kim loại cho bề mặt của các chi tiết cơ khí","Phun phủ kim loại phục hồi bề mặt của các chi tiết cơ khí","Pneumatic actuator overhaul","Pneumatic actuator testing","Positioner repair","Pressure Safety Valve Calibration Service","Pressure Safety Valve Maintenance","Pressure Safety Valve Overhaul","Pressure Safety Valve Repair Serivce","Pressure Safety Valve Testing","Pressure Safety Valve Verification Service","PSV repair","PSV testing","PSV Verification","Repair control valves","Rotork actuator maintenance service","Samson control valves","Seat Leak test as per API 598","Seat Leak test as per FCI 70-2","Seat Leakage Test as per API 527","Sửa chữa","Sửa chữa kiểm định van an toàn","Sửa chữa mặt làm kín mặt bích","Sửa chữa mặt làm kín van","Sửa chữa van","Sửa chữa van an toàn","Sửa chữa van điều khiển","Sữa chữa van điều khiển Fisher","Sữa chữa van điều khiển Masoneilan","Sữa chữa van KOMOTO","Sửa chữa van KOSO","Sửa chữa van tay","thử nghiệm van điều khiển","Valve calibration Service","valve raise face lapping","valve raise face repair","Valve Services","Valve Surface lapping"],"count_view":605,"seo_name":"dvc6200-calibration-services","date_update":1604034000,"date_created_format":1729944893,"meta_title":"DVC6200 calibration service","meta_desc":"DVC6200 calibration service","meta_keyword":"DVC6200 calibration service,Ball Valve Hydrostatic test, Ball Valve Leak test, Bảo dưỡng sửa chữa van điều khiển, bảo dưỡng thiết bị, Bảo dưỡng van, bảo trì, bảo trì van điều khiển khí nén, Butterfly Control Valve Maintenance Services, Butterfly Valve Bal","qr_code":"https:\/\/www.tkld-technical.com.vn\/dvc6200-calibration-services.html"},{"id":664386,"name":"Control Valve Servicings","desc":"","content":"<p><strong><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">CONTROL VALVE SERVICING<\/span><\/span><\/strong><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Specialist <b>Control Valve Servicing<\/b> Company for all makes\/brands – servicing, overhaul, supply of spare parts, testing and calibration<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Test standards used : ANSI B16.104\/VDI\/VDE 2174\/ FCI70-2 (Seat leak & Bubble test\/ API 598\/6D<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overhaul, testing and commissioning of Level Instruments<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Supply of Diagnostic Instruments<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Full Diagnostics monitoring and testing services<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valvelink program – for quick assembles and deliveries<\/span><\/span><\/li>\n<\/ul>\n\n<p><img src=\"\/datafiles\/40367\/upload\/images\/TKLD%20Control%20valve%20servicing.jpeg\" style=\"width: 800px; height: 1067px;\" \/><\/p>\n","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/Control%20Valve%20Services\/Masoneilan%2020%20inch%20Anti%20surge%20valve.JPG","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/Control%20Valve%20Services\/Masoneilan%2020%20inch%20Anti%20surge%20valve.JPG","tags":["Control Valve Servicing","Ball Valve Hydrostatic test","Ball Valve Leak test","Bảo dưỡng sửa chữa van điều khiển","bảo dưỡng thiết bị","Bảo dưỡng van","bảo trì","bảo trì van điều khiển khí nén","Butterfly Control Valve Maintenance Services","Butterfly Valve Ball Valve Hydrostatic test","Check Valve Hydrostatic test","Check Valve Leak test","Control Valve Cablibration","Control Valve Calibration","Control valve calibration service","Control Valve Calibration Services","Control valve commissioning and testing","Control Valve Hydrostatic test","Control Valve Inspection","Control Valve Inspection and Calibration","Control valve inspection and testing","Control Valve Inspection Service","Control Valve Maintenance and Testing","Control Valve Maintenance Services","Control valve maintenance training","Control Valve Overhaul","Control valve overhaul training","Control valve pre-commissioning","Control Valve Repair","Control Valve Repair Serivce","Control Valve Seat Leak test","Control Valve Services","Control Valve Testing","Control Valve Testing Service","Dịch vụ bảo dưỡng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Cầu","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Mặt Bích Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van an toàn","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van Cổng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điện","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điều khiển","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van một chiều","Dịch vụ bảo trì sửa chữa van công nghiệp","Dịch vụ cân chỉnh van điều khiển","Dịch vụ đào tạo bảo dưỡng sửa chữa van điều khiển","Dịch vụ đào tạo bảo dưỡng van","Dịch vụ đào tạo hiệu chỉnh van điều khiển","Dịch vụ đào tạo loop check hệ thống điện","Dịch vụ đào tạo loop check hệ thống điều khiển","Dịch vụ đào tạo loop check van điều khiển","Dịch vụ đào tạo loop test hệ thống điện","Dịch vụ đào tạo loop test hệ thống điều khiển","Dịch vụ đào tạo loop test hệ thống điiều khiển","Dịch vụ đào tạo loop test van điều khiển","Dịch vụ đào tạo sửa chữa van","Dịch vụ đào tạo sửa chữa van điều khiển","Dịch vụ hiệu chuẩn van điều khiển","Dịch vụ hydrotest van","Dịch vụ mài rà mặt làm kín van","Dịch vụ mài rà van cổng","Dịch vụ mài rà van dao","Dịch vụ sửa chữa bảo dưỡng van điện","Dịch vụ sửa chữa bảo dưỡng van tay","Dịch vụ sửa chữa bảo dưỡng van thủy lực","Dịch vụ sửa chữa bộ điều khiển van","Dịch Vụ sửa chữa mặt làm kín van","DỊCH VỤ SỬA CHỮA TẤT CẢ CÁC LOẠI VAN","Dịch vụ sửa chữa van","Dịch vụ sửa chữa van bi","Dịch vụ sửa chữa van bướm","Dịch vụ sửa chữa van công nghiệp","Dịch vụ sửa chữa van một chiều","Dịch vụ thử áp đường ống","Dịch vụ thử áp hệ thống","Dịch vụ thử áp van điều khiển","Dịch vụ thử rò rỉ van điều khiển","Dịch vụ thử rò rỉ van tay","Dịch vụ thử rò van điều khiển","Dịch vụ thử thuỷ lực thân van","Dịch vụ thử thuỷ lực van điều khiển","Dịch vụ thử thuỷ lực van tay","Fucntion test control valves","Gate Valve Hydrostatic test","Gate Valve Leak test","Gate Valve Repair Serivce","Gia công mặt làm kín van","Globe Control Valve Maintenance Services","Globe Valve Hydrostatic test","Globe Valve Leak test","Hiệu chỉnh van điều khiển","Hiệu chuẩn van điều khiển","Hydrostatic test as per API 598","Hydrostatic test as per API 6D","lắp đặt van điều khiển khí nén","Manual valve hydrostatic test","Manual valve leak test","Manual Valve Repair Serivce","Manual valve testing","On-Off Valve Hydrostatic test","On-Off Valve Repair Serivce","On-Off Valve Seat Leak test","Overhaul Control Valves","phục hồi các loại van","Phun phủ kim loại","Phun phủ kim loại cho bề mặt của các chi tiết cơ khí","Phun phủ kim loại phục hồi bề mặt của các chi tiết cơ khí","Pneumatic actuator overhaul","Pneumatic actuator testing","Positioner repair","Pressure Safety Valve Calibration Service","Pressure Safety Valve Maintenance","Pressure Safety Valve Overhaul","Pressure Safety Valve Repair Serivce","Pressure Safety Valve Testing","Pressure Safety Valve Verification Service","PSV repair","PSV testing","PSV Verification","Repair control valves","Rotork actuator maintenance service","Samson control valves","Seat Leak test as per API 598","Seat Leak test as per FCI 70-2","Seat Leakage Test as per API 527","Sửa chữa","Sửa chữa kiểm định van an toàn","Sửa chữa mặt làm kín mặt bích","Sửa chữa mặt làm kín van","Sửa chữa van","Sửa chữa van an toàn","Sửa chữa van điều khiển","Sữa chữa van điều khiển Fisher","Sữa chữa van điều khiển Masoneilan","Sữa chữa van KOMOTO","Sửa chữa van KOSO","Sửa chữa van tay","thử nghiệm van điều khiển","Valve calibration Service","valve raise face lapping","valve raise face repair","Valve Services","Valve Surface lapping"],"count_view":524,"seo_name":"control-valve-servicings","date_update":1604034000,"date_created_format":1729944505,"meta_title":"Control Valve Servicing","meta_desc":"Control Valve Servicing","meta_keyword":"Control Valve Servicing,Ball Valve Hydrostatic test, Ball Valve Leak test, Bảo dưỡng sửa chữa van điều khiển, bảo dưỡng thiết bị, Bảo dưỡng van, bảo trì, bảo trì van điều khiển khí nén, Butterfly Control Valve Maintenance Services, Butterfly Valve Ball Va","qr_code":"https:\/\/www.tkld-technical.com.vn\/control-valve-servicings.html"},{"id":662475,"name":"Calibration Fisher DVC6200 Positioners","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Hoặc : 0987056271- Mr. Kiếm<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Email: technical.manager@tkld.com.vn<\/span><\/span><\/p>\n","content":"<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Based on our professional engineering control valve experience, we would detail the operational principles, technical specifications, and steps for troubleshooting or calibrating the Fisher DVC6200 positioner. This device is commonly used in industrial applications to control valve positions, ensuring precision and efficiency in fluid handling systems. This article includes information on how the positioner interprets control signals, adjusts valve positions accordingly, and the feedback mechanisms it employs to maintain control accuracy. Additionally, debugging sections would cover common issues, diagnostic procedures, and adjustment techniques to ensure optimal performance.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"fisher dvc6200 calibration\" decoding=\"async\" fetchpriority=\"high\" height=\"214\" sizes=\"(max-width: 236px) 100vw, 236px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Fisher-DVC6200-calibration.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Fisher-DVC6200-calibration.jpg 236w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Fisher-DVC6200-calibration-64x58.webp 64w\" width=\"236\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Fisher DVC6200<\/span><\/span><\/figcaption>\n<\/figure>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The Fisher DVC6200 Digital Valve Controllers, abbreviated as DVC, represent a series model in the development of Fisher’s DVC positioners. The DVC6200 is developed by integrating the features of the DVC2000 and DVC6000 series, resulting in a valve positioner that boasts high applicability and reliability.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"control valve with dvc6200\" decoding=\"async\" height=\"329\" sizes=\"(max-width: 557px) 100vw, 557px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/control-valve-with-DVC6200-jpg.webp\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/control-valve-with-DVC6200-jpg.webp 557w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/control-valve-with-DVC6200-300x177.webp 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/control-valve-with-DVC6200-64x38.webp 64w\" width=\"557\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Control Valve with DVC6200<\/span><\/span><\/figcaption>\n<\/figure>\n\n<h2 id=\"What_is_DVC6200_Positioner\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">What is DVC6200 Positioner<\/span><\/span><\/h2>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The Fisher DVC6200 digital positioner with the 67CFR filter regulator designed for pneumatic control valves, such as model ET, EZ, EWT etc,.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The FIELDVUE DVC6200 system enhances operational efficiency by enabling more precise control, thereby driving the process closer to its setpoint and significantly enhancing product quality. Leveraging FIELDVUE Performance Diagnostics, this instrument offers real-time valve operation monitoring to assess performance and reliability meticulously.<\/span><\/span><\/p>\n\n<h3 id=\"DVC6200_Digital_Positioner_Specifications\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">DVC6200 Digital Positioner Specifications<\/span><\/span><\/h3>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Area Classification<\/strong>: Designed to meet rigorous standards, including Explosion Proof, Intrinsically Safe, FISCO, Type N, Flame Proof, and Non-incendive for FM.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Certifications<\/strong>: Comprehensive certifications such as CSA, FM, ATEX, IECEx, CUTR, Lloyd’s Register, Peso, KGS, INMETRO, NEPSI, TIIS, certified for Natural Gas, and recognized as a Single Seal Device.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Communication Protocol<\/strong>: Utilizes HART® 4-20 mA for reliable data transmission.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Data Interface<\/strong>: Offers a wired connection for secure data communication.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Diagnostics<\/strong>: Embedded diagnostics for enhanced performance monitoring.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Input Signal<\/strong>: Electric, ensuring versatile applicability.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Max Outlet Pressure<\/strong>: Capable of reaching up to 145 psig.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Mounting Type: Features an integral mounting design.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Operating Temperature<\/strong>: Supports both standard and high-temperature operations.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Position Control<\/strong>: Offers throttling control and on\/off capabilities.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Power Source<\/strong>: Operates with a local power source.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Process Control<\/strong>: Facilitates control over flow, pressure, temperature, and level.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Supply Media<\/strong>: Compatible with air, natural gas, and nitrogen.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">For additional configurations and specifications, we encourage you to consult with your local Emerson business partner or sales office.<\/span><\/span><\/p>\n\n<h3 id=\"DVC6200_Digital_Features\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">DVC6200 Digital Features<\/span><\/span><\/h3>\n\n<ol>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The DVC6200 features a high-performance, linkage-less feedback system, which eliminates wear on parts by avoiding physical contact.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Its fully encapsulated electronics are designed to withstand vibration, temperature fluctuations, and corrosive environments.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Offers rapid response to significant step changes and delivers precise control over minor setpoint adjustments.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">As a HART communicating device, the DVC6200 ensures easy access to information throughout the loop, minimizing the need for direct interaction in hazardous environments and simplifying valve evaluations in difficult-to-access areas.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Its modular design permits the replacement of critical components without the need to disconnect field wiring or pneumatic tubing.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Integration into control systems can yield considerable savings on hardware and installation costs.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The self-diagnostic feature of the DVC6200 offers comprehensive insights into valve performance and health, ensuring optimal operation.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Digital communication enhances the accessibility of valve conditions, facilitating maintenance and operation.<\/span><\/span><\/li>\n<\/ol>\n\n<h3 id=\"Instrument_Level_Capabilities_of_Fisher_DVC6200_Digital_Valve_Controller\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Instrument Level Capabilities of Fisher DVC6200 Digital Valve Controller<\/span><\/span><\/h3>\n\n<figure>\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td rowspan=\"2\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">CAPABILITY<\/span><\/span><\/td>\n\t\t\t<td colspan=\"5\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">DIAGNOSTIC LEVEL<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">AC<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">HC<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">AD<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">PD<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">ODV<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Auto Calibration<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Custom Characterization<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Burst Communication<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Alerts<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step Response,Drive Signal Test & Dynamic Error Band<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Advanced Diagnostics (Valve Signature)<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Performance Tuner<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Travel Control Pressure Fallback<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Supply Pressure Sensor<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Performance Diagnostics<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solenoid Valve Testing<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Lead Lag Set Point Filter<\/span><\/span><\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td> <\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">X<\/span><\/span><\/td>\n\t\t<\/tr>\n\t<\/tbody>\n<\/table>\n<\/figure>\n\n<h3 id=\"Principle_of_the_DVC6200_Double_Acting_Digital_Positioner\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Principle of the DVC6200 Double Acting Digital Positioner<\/span><\/span><\/h3>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"wiring dvc6200\" decoding=\"async\" height=\"394\" sizes=\"(max-width: 569px) 100vw, 569px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/wiring-DVC6200-jpg.webp\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/wiring-DVC6200-jpg.webp 569w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/wiring-DVC6200-300x208.webp 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/wiring-DVC6200-64x44.webp 64w\" width=\"569\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">wiring dvc6200<\/span><\/span><\/figcaption>\n<\/figure>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The input control signal of 4-20mA DC from the control system is transmitted via signal lines to the terminal box. The electronic module processor within the positioner reads the input control signal and the valve position feedback signal. After digital processing, it converts these signals into an analog control drive signal for the I\/P electrical converter. The I\/P converter then transforms the electrical signal into a pneumatic signal, which is power amplified by a pneumatic amplifier, providing two pneumatic outputs.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"principle of the dvc6200 double acting digital positioner\" decoding=\"async\" height=\"389\" loading=\"lazy\" sizes=\"(max-width: 579px) 100vw, 579px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner-jpg.webp\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner-jpg.webp 579w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner-300x202.webp 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner-64x43.webp 64w\" width=\"579\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">principle of the dvc6200 double acting digital positioner<\/span><\/span><\/figcaption>\n<\/figure>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">For instance, as the signal increases, the air pressure at output A increases while the air pressure at output B decreases. When the signal is set to 12mA, the air pressures at outputs A and B are approximately equal. Conversely, when the signal decreases, the air source at output B increases, and the air source at output A decreases. The pneumatic output from the digital valve positioner is then directed to the pneumatic actuator of the control valve, causing the valve stem position to change. Consequently, the position of the magnetic strip also changes. A Hall sensor detects this change in valve position and sends the signal back to the electronic module. The positioning control process concludes when the valve position aligns with the input control signal, stabilizing the signal from the I\/P electrical converter and the output air pressure from the pneumatic amplifier, with minimal deviation.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"principle of the dvc6200 double acting digital positioner3\" decoding=\"async\" height=\"407\" loading=\"lazy\" sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner3-1024x407.webp\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner3-1024x407.webp 1024w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner3-300x119.webp 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner3-768x305.webp 768w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner3-600x238.webp 600w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner3-64x25.webp 64w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Principle-of-the-DVC6200-Double-Acting-Digital-Positioner3-jpg.webp 1080w\" width=\"1024\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">principle of the dvc6200 double acting digital positioner3<\/span><\/span><\/figcaption>\n<\/figure>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Difference of Digital Positioner DVC6200 Terminal Box with Feedback Signal or Not<\/span><\/span><\/h4>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"dvc6200 double acting digital positioner with feedback\" decoding=\"async\" height=\"410\" loading=\"lazy\" sizes=\"(max-width: 433px) 100vw, 433px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/DVC6200-Double-Acting-Digital-Positioner-with-feedback-jpg.webp\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/DVC6200-Double-Acting-Digital-Positioner-with-feedback-jpg.webp 433w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/DVC6200-Double-Acting-Digital-Positioner-with-feedback-300x284.webp 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/DVC6200-Double-Acting-Digital-Positioner-with-feedback-64x61.webp 64w\" width=\"433\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">dvc6200 double acting digital positioner with feedback<\/span><\/span><\/figcaption>\n<\/figure>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"dvc6200 double acting digital positioner without feedback\" decoding=\"async\" height=\"315\" loading=\"lazy\" sizes=\"(max-width: 356px) 100vw, 356px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/DVC6200-Double-Acting-Digital-Positioner-without-feedback-jpg.webp\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/DVC6200-Double-Acting-Digital-Positioner-without-feedback-jpg.webp 356w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/DVC6200-Double-Acting-Digital-Positioner-without-feedback-300x265.webp 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/DVC6200-Double-Acting-Digital-Positioner-without-feedback-64x57.webp 64w\" width=\"356\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">dvc6200 double acting digital positioner without feedback<\/span><\/span><\/figcaption>\n<\/figure>\n\n<h3 id=\"The_IP_Electrical_Converter—Transforms_Electrical_Signals_into_Pneumatic_Signals\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The I\/P Electrical Converter—Transforms Electrical Signals into Pneumatic Signals<\/span><\/span><\/h3>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The air supply passes through a constant throttle orifice (constant air resistance) to the nozzle. The drive signal from the electronic module controls the coil of the I\/P converter, attracting the armature to act. This movement of the armature moves the flapper closer to the nozzle, causing an increase in the back pressure at the nozzle. This increase translates to a higher pneumatic signal sent to the pneumatic amplifier, ultimately resulting in an increase in the output air pressure from the valve positioner. When the drive signal is reduced, the electromagnetic coil causes the armature\/flapper to move away from the nozzle, reducing its back pressure and, consequently, the output from the pneumatic amplifier decreases.<\/span><\/span><\/p>\n\n<p> <\/p>\n\n<h2 id=\"How_to_Install_Fisher_Digital_Positioner_DVC6200_\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">How to Install Fisher Digital Positioner DVC6200<\/span><\/span><\/h2>\n\n<h3 id=\"How_to_Install_and_Assembly_DVC6200_to_Sliding_StemLinear_Type_Control_Valves\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">How to Install and Assembly DVC6200 to Sliding Stem\/Linear Type Control Valves<\/span><\/span><\/h3>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"Play: Video\" aria-label=\"Play: Video\" id=\"fallbackPlaceholder\" loading=\"lazy\" referrerpolicy=\"origin\" src=\"https:\/\/i.ytimg.com\/vi\/SBr99gejyII\/hqdefault.jpg\" \/><button aria-label=\"Play: Video\" id=\"playButton\"><\/button><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Resource from <strong>Fisher Valves & Instruments<\/strong><\/span><\/span><\/figcaption>\n<\/figure>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"mounting the dvc6200 digital valve controller1\" decoding=\"async\" height=\"335\" loading=\"lazy\" sizes=\"(max-width: 796px) 100vw, 796px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller1.png\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller1.png 796w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller1-300x126.png 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller1-768x323.png 768w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller1-600x253.png 600w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller1-64x27.png 64w\" width=\"796\" \/><\/span><\/span><\/figure>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"mounting the dvc6200 digital valve controller2\" decoding=\"async\" height=\"321\" loading=\"lazy\" sizes=\"(max-width: 784px) 100vw, 784px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller2.png\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller2.png 784w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller2-300x123.png 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller2-768x314.png 768w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller2-600x246.png 600w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller2-64x26.png 64w\" width=\"784\" \/><\/span><\/span><\/figure>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"mounting the dvc6200 digital valve controller3\" decoding=\"async\" height=\"339\" loading=\"lazy\" sizes=\"(max-width: 784px) 100vw, 784px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller3.png\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller3.png 784w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller3-300x130.png 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller3-768x332.png 768w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller3-600x259.png 600w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2024\/03\/Mounting-the-DVC6200-Digital-Valve-Controller3-64x28.png 64w\" width=\"784\" \/><\/span><\/span><\/figure>\n\n<h3 id=\"How_to_Install_and_Assembly_DVC6200_to_Rotary_Type_Control_Valves\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">How to Install and Assembly DVC6200 to Rotary Type Control Valves<\/span><\/span><\/h3>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"Play: Video\" aria-label=\"Play: Video\" id=\"fallbackPlaceholder\" loading=\"lazy\" referrerpolicy=\"origin\" src=\"https:\/\/i.ytimg.com\/vi\/bApJdlDl8To\/hqdefault.jpg\" \/><button aria-label=\"Play: Video\" id=\"playButton\"><\/button><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Resource from <strong>Fisher Valves & Instruments<\/strong><\/span><\/span><\/figcaption>\n<\/figure>\n\n<h2 id=\"How_use_375_or_475_Field_communicator_to_Calibrate_Fisher_DVC6200_Digital_Positioner\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">How Use 375 Or 475 Field Communicator To Calibrate Fisher DVC6200 Digital Positioner<\/span><\/span><\/h2>\n\n<h3 id=\"Step_1_Initial_Connection\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 1. Initial Connection<\/span><\/span><\/h3>\n\n<ol>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Connect a HART® communicator to the DVC6200, ensuring it is in parallel with a 4-20 mA loop across the “loop” terminals.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Apply a 4 mA signal to the DVC6200 and activate the HART communicator.<\/span><\/span><\/li>\n<\/ol>\n\n<h3 id=\"Step_2_Switching_Instrument_Mode\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 2. Switching Instrument Mode<\/span><\/span><\/h3>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Navigate to the instrument’s menu and select ‘Configure’, followed by ‘Detailed Setup’, then ‘Mode and Protection’, and finally ‘Instrument Mode’.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Select “Not in Service” and confirm by pressing ‘Enter’.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To return to the main menu, press the home key.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"Step_3_Commencing_Configuration\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 3. Commencing Configuration<\/span><\/span><\/h3>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Proceed by selecting ‘Configure’, then ‘Guided Setup’, followed by ‘Setup Wizard’.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The ‘Setup Wizard’ will initiate a series of configuration prompts. You will be asked to provide details about the actuator and valve, including the manufacturer, type, size, and supply pressure requirements.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"Step_4_Factory_Defaults_and_Setup_Wizard_Completion\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 4. Factory Defaults and Setup Wizard Completion<\/span><\/span><\/h3>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When prompted, opt to send the factory defaults as an initial setting. Note that fine-tuning adjustments can be made subsequently.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Complete the setup wizard as instructed by the communicator, which will then direct you to initiate the auto-travel calibration process.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"Step_5_Auto-Travel_Calibration\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 5. Auto-Travel Calibration<\/span><\/span><\/h3>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Select the manual method when prompted for the adjustment method for output bias.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The communicator will automatically actuate the valve to both 100% and 0% travel, adjusting the output bias accordingly.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Upon reaching the prompt for 50%, adjust the mA input to 12 mA and continue with the auto-travel calibration as instructed.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"Step_6_Finalizing_Configuration\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 6. Finalizing Configuration<\/span><\/span><\/h3>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Following the auto-travel calibration, the communicator will prompt a return to “In Service” mode. Comply with this request.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Perform a complete valve stroke to ensure that the valve opens linearly in response to the 4-20 mA input signal.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">This process is designed to ensure that your DVC6200 controller is calibrated accurately and operates efficiently. For optimal performance, adhere closely to each step and make adjustments as necessary based on the specific requirements of your actuator and valve configuration. Should you have any questions, please feel free to contact TKLD's consultation team.<\/span><\/span><\/p>\n","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/DAM%20CA%20MAU%202023\/ca%20mau%202023-2%281%29.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/DAM%20CA%20MAU%202023\/ca%20mau%202023-2%281%29.jpg","tags":["Calibration Fisher DVC6200 Positioner","Siemens SIPART PS2 Troubleshooting","Troubleshooting of Siemens SIPART PS2","Troubleshooting of Siemens SIPART PS2 Valve Positioner","Sipart Ps2 Positioner Calibration Procedure","Siemens PS2 Positioner Calibration","Siemens sipart ps2 calibration","Calibration SIPART PS2 Valve Positioner","Calibration the SIPART PS2 Valve Positioner","Ball Valve Hydrostatic test","Ball Valve Leak test","Bảo dưỡng sửa chữa van điều khiển","bảo dưỡng thiết bị","Bảo dưỡng van","bảo trì","bảo trì van điều khiển khí nén","Butterfly Control Valve Maintenance Services","Butterfly Valve Ball Valve Hydrostatic test","Check Valve Hydrostatic test","Check Valve Leak test","Control Valve Cablibration","Control Valve Calibration","Control valve calibration service","Control Valve Calibration Services","Control valve commissioning and testing","Control Valve Hydrostatic test","Control Valve Inspection","Control Valve Inspection and Calibration","Control valve inspection and testing","Control Valve Inspection Service","Control Valve Maintenance and Testing","Control Valve Maintenance Services","Control valve maintenance training","Control Valve Overhaul","Control valve overhaul training","Control valve pre-commissioning","Control Valve Repair","Control Valve Repair Serivce","Control Valve Seat Leak test","Control Valve Services","Control Valve Testing","Control Valve Testing Service","Dịch vụ bảo dưỡng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Cầu","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Mặt Bích Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van an toàn","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van Cổng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điện","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điều khiển","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van một chiều","Dịch vụ bảo trì sửa chữa van công nghiệp","Dịch vụ cân chỉnh van điều khiển","Dịch vụ đào tạo bảo dưỡng sửa chữa van điều khiển","Dịch vụ đào tạo bảo dưỡng van","Dịch vụ đào tạo hiệu chỉnh van điều khiển","Dịch vụ đào tạo loop check hệ thống điện","Dịch vụ đào tạo loop check hệ thống điều khiển","Dịch vụ đào tạo loop check van điều khiển","Dịch vụ đào tạo loop test hệ thống điện","Dịch vụ đào tạo loop test hệ thống điều khiển","Dịch vụ đào tạo loop test hệ thống điiều khiển","Dịch vụ đào tạo loop test van điều khiển","Dịch vụ đào tạo sửa chữa van","Dịch vụ đào tạo sửa chữa van điều khiển","Dịch vụ hiệu chuẩn van điều khiển","Dịch vụ hydrotest van","Dịch vụ mài rà mặt làm kín van","Dịch vụ mài rà van cổng","Dịch vụ mài rà van dao","Dịch vụ sửa chữa bảo dưỡng van điện","Dịch vụ sửa chữa bảo dưỡng van tay","Dịch vụ sửa chữa bảo dưỡng van thủy lực","Dịch vụ sửa chữa bộ điều khiển van","Dịch Vụ sửa chữa mặt làm kín van","DỊCH VỤ SỬA CHỮA TẤT CẢ CÁC LOẠI VAN","Dịch vụ sửa chữa van","Dịch vụ sửa chữa van bi","Dịch vụ sửa chữa van bướm","Dịch vụ sửa chữa van công nghiệp","Dịch vụ sửa chữa van một chiều","Dịch vụ thử áp đường ống","Dịch vụ thử áp hệ thống","Dịch vụ thử áp van điều khiển","Dịch vụ thử rò rỉ van điều khiển","Dịch vụ thử rò rỉ van tay","Dịch vụ thử rò van điều khiển","Dịch vụ thử thuỷ lực thân van","Dịch vụ thử thuỷ lực van điều khiển","Dịch vụ thử thuỷ lực van tay","Fucntion test control valves","Gate Valve Hydrostatic test","Gate Valve Leak test","Gate Valve Repair Serivce","Gia công mặt làm kín van","Globe Control Valve Maintenance Services","Globe Valve Hydrostatic test","Globe Valve Leak test","Hiệu chỉnh van điều khiển","Hiệu chuẩn van điều khiển","Hydrostatic test as per API 598","Hydrostatic test as per API 6D","lắp đặt van điều khiển khí nén","Manual valve hydrostatic test","Manual valve leak test","Manual Valve Repair Serivce","Manual valve testing","On-Off Valve Hydrostatic test","On-Off Valve Repair Serivce","On-Off Valve Seat Leak test","Overhaul Control Valves","phục hồi các loại van","Phun phủ kim loại","Phun phủ kim loại cho bề mặt của các chi tiết cơ khí","Phun phủ kim loại phục hồi bề mặt của các chi tiết cơ khí","Pneumatic actuator overhaul","Pneumatic actuator testing","Positioner repair","Pressure Safety Valve Calibration Service","Pressure Safety Valve Maintenance","Pressure Safety Valve Overhaul","Pressure Safety Valve Repair Serivce","Pressure Safety Valve Testing","Pressure Safety Valve Verification Service","PSV repair","PSV testing","PSV Verification","Repair control valves","Rotork actuator maintenance service","Samson control valves","Seat Leak test as per API 598","Seat Leak test as per FCI 70-2","Seat Leakage Test as per API 527","Sửa chữa","Sửa chữa kiểm định van an toàn","Sửa chữa mặt làm kín mặt bích","Sửa chữa mặt làm kín van","Sửa chữa van","Sửa chữa van an toàn","Sửa chữa van điều khiển","Sữa chữa van điều khiển Fisher","Sữa chữa van điều khiển Masoneilan","Sữa chữa van KOMOTO","Sửa chữa van KOSO","Sửa chữa van tay","thử nghiệm van điều khiển","Valve calibration Service","valve raise face lapping","valve raise face repair","Valve Services","Valve Surface lapping"],"count_view":1887,"seo_name":"calibration-fisher-dvc6200-positioners","date_update":1728532800,"date_created_format":1728879569,"meta_title":"Calibration Fisher DVC6200 Positioners","meta_desc":"Calibration Fisher DVC6200 Positioners","meta_keyword":"Calibration Fisher DVC6200 Positioner,Siemens SIPART PS2 Troubleshooting,Troubleshooting of Siemens SIPART PS2 ,Troubleshooting of Siemens SIPART PS2 Valve Positioner,Sipart Ps2 Positioner Calibration Procedure,Siemens PS2 Positioner Calibration,Siemens s","qr_code":"https:\/\/www.tkld-technical.com.vn\/calibration-fisher-dvc6200-positioners.html"},{"id":662450,"name":"Troubleshooting of Siemens SIPART PS2 Valve Positioners","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Hoặc : 0987056271- Mr. Kiếm<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Email: technical.manager@tkld.com.vn<\/span><\/span><\/p>\n","content":"<h1><span style=\"font-size:20px;\"><strong><span style=\"font-family:Times New Roman,Times,serif;\">Troubleshooting of Siemens SIPART PS2 Valve Positioner<\/span><\/strong><\/span><\/h1>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">SIPART PS2 is a widely used positioner for sliding and rotary actuators in the process industry. It has a particularly flexible stroke range, intelligent diagnostics, and available HART, PROFIBUS PA communication, or FF communication. Siemens intelligent valve positioner is a good choice for control valves, and we always put this brand as our first option. <\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Since many customers meet problems with the positioner on site that cannot be solved, we list the common failures in this article to provide solutions for field engineers<\/span><\/span><\/p>\n\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=FNg0UUyGZC0\">https:\/\/www.youtube.com\/watch?v=FNg0UUyGZC0<\/a><\/p>\n\n<h3 id=\"1_Pneumatic_Actuator_Blow-By_double-acting_only_\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Pneumatic Actuator Blow-By (double-acting only) <\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve won’t calibrate<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overshoot\/undershoot<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve position deviation<\/span><\/span><\/li>\n<\/ul>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"ps2 positioner parts\" decoding=\"async\" height=\"568\" sizes=\"(max-width: 714px) 100vw, 714px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-parts.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-parts.jpg 714w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-parts-300x239.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-parts-600x477.jpg 600w\" width=\"714\" \/><\/span><\/span><\/figure>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">This problem is only found in pneumatic double-acting actuators that are utilizing both Y1 and Y2 output ports.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">One output port adds air pressure while the other exhausts air pressure<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">This creates the necessary differential pressure in the actuator to move the valve.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The two air chambers in the actuator must be isolated from each other; otherwise, the differential pressure cannot increase.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The actuator has an internal leak and needs to be repaired for blew issues.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">a. Air is continuously blown out of the exhaust port when trying to move the valve to a new position.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">b. When attempting to move the valve to a new position, the two output pressure gauges, Y1 and Y2, have relatively equal pressure values.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"ps2 positioner button meaning\" decoding=\"async\" height=\"345\" loading=\"lazy\" sizes=\"(max-width: 428px) 100vw, 428px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-button-meaning.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-button-meaning.jpg 428w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-button-meaning-300x242.jpg 300w\" width=\"428\" \/><\/span><\/span><\/figure>\n\n<h3 id=\"2_Actuator_End_Stops\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">2 Actuator End Stops<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does no fully close\/open<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The actuator end stop is operable and must be set properly for each valve application. If not set correctly, the actuator will allow the valve to enter the seat excessively, or over-rotate the valve in the open position. This can damage the valve and result in bad process performance.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>To identify improper end-stop settings:<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Review actuator\/valve manual and determine proper end-stops settings for the valve.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Put PS2 in manual mode:<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"> From Auto press the Operating mode button <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>once.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Use the Increment button <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or Decrement button <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>to change the valve position<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Using the Increment button <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or Decrement buttons <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>move the valve to both end-stop positions and determine if<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">a valve is seating properly.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● If necessary make adjustments to actuator end-stops, refer to the actuator’s service manual for details.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Re-initialize PS2<\/span><\/span><\/p>\n\n<h3 id=\"3_Air_Leak_\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">3 Air Leak <\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Drifts off setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Always going to alarm<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Not responding input<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not fully close\/open<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve position deviation<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Note: For firmware 5.00.00 or greater only: Verify parameter “PNEUM” is set correctly:<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• “Std” = Standard Valve Block or<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• “FIP” = Fail In Place Valve Block (“F10” at the end of the model code indicates FIP option.)<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Perform a leak test. Any number greater than 1.0 % will need to be corrected to prevent premature wear of the pneumatic valve block.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● From Manual or “noini” mode, drive the valve to a mid-stroke position using the Increment button and\/or Decrement buttons.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Press and hold all three buttons down for at least 2 seconds.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– PS2 will now be in Diagnostic mode, with a diagnostic number in the lower left-hand corner of the display.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Press the operating mode button to advance through the diagnostic menu.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Go to diagnostic: “LEAK”.Press and hold the increment button for at least 5 seconds.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Display will flash between “test” and actual position.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– After one minute, the screen will display the leak rate in percent of travel from original positon.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● To return to Automatic mode, press and hold the operating mode button for 5 seconds.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– The unit will now be in Manual mode.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press the Operating mode button one time to return to Automatic mode.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● If the leak is detected, check pneumatic fittings, air lines, and actuator.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Use some form of leak detection or soap and water around the pneumatic connections taking care not to wet the internals of the unit.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Identify leak and use appropriate method(s) for leak correction.<\/span><\/span><\/p>\n\n<h3 id=\"4_Alarm_Parameters\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">4 Alarm Parameters<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Always going to alarm<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If the unit is always going into alarm, verify configuration settings.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Parameter “AFCT” (Default is OFF)<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– From AUT or MAN mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds. Now observe the number in the lower left-hand corner.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Continue to press the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until Parameter “AFCT” is reached.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– This parameter should be set to “OFF”.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/> to change option.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Parameters ” TIM” & ” LIM”<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Note: These parameters should never be set to zero. <\/span><\/span><\/p>\n\n<h3 id=\"5_Booster_Not_Properly_Tuned_\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">5 Booster Not Properly Tuned <\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overshoot\/undershoot<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too fast<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The pneumatic volume booster should always be equipped with a bypass needle valve. This needle valve may be external or integral to the booster housing. Adjustment of the needle valve is necessary to achieve proper valve response.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If PS2 is in Auto and currently operating the valve:<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Rotate the needle valve counter-clockwise to slowdown response and reduce overshoots.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Rotate the needle valve clockwise to increase valve response<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Re-initialize PS2 after any needle valve adjustments; see Initialization Procedure (Page 50)(see Appendix).<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">A volume booster must be setup BEFORE initializing a valve positioner. The P-manual mode (“NOINI” flashing), see display example below, can be used to perform this setup.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"noini\" decoding=\"async\" height=\"89\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/NOINI.jpg\" width=\"150\" \/><\/span><\/span><\/figure>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The P-manual mode will appear once proper electrical power is applied to a new PS2 valve positioner.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If PS2 is currently initialized, activate “NOINI” mode:<br \/>\n– Press and hold <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button to enter configuration mode<br \/>\n– Configuration parameter number appears in lower left corner of display.<br \/>\n– Use <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/> button to reach parameter: “4 INITA”.Press and hold <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button until “no”<br \/>\nappears on top of display.<br \/>\n– Press and hold <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button to exit configuration mode<br \/>\n– Display will be similar to the following (numerical value will vary).<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Once all pneumatic connections are made, and the appropriate supply pressure is applied, moving the valve assembly throughout the entire valve stroke can be accomplished using the <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button\/s.<br \/>\n– Pressing one button delivers air slowly to the actuator.<br \/>\n– Pressing and holding one button and then pressing and holding the other button will deliver air quickly to the actuator.<br \/>\n– To move valve assembly in the opposite direction, reverse the two push button sequence.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If the valve assembly does not move, it may be possible that the valve assembly is at the actuator end-stop position. Therefore, alternate push button sequence to deliver air in the opposite direction.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Using <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons, move valve assembly to each end-stop position.<br \/>\nSince the numerical value on the display is an un-calibrated value, use a mechanical indicator on valve assembly to determine the actual valve position.<br \/>\n– Move valve assembly to a mid-travel position and release pushbuttons.<br \/>\nOnce push buttons are released valve assembly should immediately stop.<br \/>\nIf valve assembly continues to move, adjust needle valve\/s a quarter-turn counterclockwise.<br \/>\n– Repeat the above procedure until valve assembly stops when push buttons are released at any travel position.<br \/>\nIf this cannot be accomplished, check for air leaks and\/or replace volume boosters.<\/span><\/span><\/p>\n\n<h3 id=\"6_Change_in_Valve_Travel\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">6 Change in Valve Travel<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve is not repeatable<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not fully close\/open<\/span><\/span><\/li>\n<\/ul>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Process Material Build-up<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">After the valve has been in operation for a long time, process material may build up on the valve and seat, which will prevent the valve from closing completely and cause the media to leak through the seat. In addition, process material buildup can also prevent the valve from opening completely.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To identify this possible, please step by step to check it.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Put PS2 valve positioner in Manual mode- from Auto, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button once.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">While pressing and holding <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>button, press and hold <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button. This will move the valveto an end-stop position. To move valve in opposite direction, reverse push button sequence; while pressing and holding<img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/> button, press and hold<img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use this two-push button method to drive the valve fully open and fully closed.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Utilize pressure gauges to determine if PS2 is outputting full supply pressure and exhausting all output pressure.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>-For single-acting (one air pipeline to the actuator)<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">One end-stop position should show full supply pressure. The other end-stop position will show zero pressure.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>-For double-acting (two air pipelines to the actuator)<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">One end-stop position should show full supply pressure, while the other gauge should show zero pressure. Output pressures will be reversed when driving the valve to other end-stop positions, see the following example of double-acting pressure gauges at each end-stop position.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"pressure gauge\" decoding=\"async\" height=\"226\" loading=\"lazy\" sizes=\"(max-width: 227px) 100vw, 227px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/pressure-gauge.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/pressure-gauge.jpg 227w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/pressure-gauge-150x150.jpg 150w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/pressure-gauge-100x100.jpg 100w\" width=\"227\" \/><\/span><\/span><\/figure>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If PS2 can output full supply and exhaust in both directions, then something else is preventing the actuator from fully closing or opening.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Verify supply pressure is properly set.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If a valve is still not able to fully close or open, then check the actuator\/valve for:<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Mechanical binding<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Valve seat wear<\/span><\/span><\/p>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve Seat Wear<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve and valve seat wear can cause over-travel and process leaks.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To Identify this:<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Put PS2 in Manual mode- from Auto, press<img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/> button once.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">While pressing and holding <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>button, press and hold <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button. This will move the valve to an end-stop position. To move valve in opposite direction, reverse push button sequence; while pressing and holding <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button, press and hold<img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/> .<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use this two-push button method to drive valve fully open and fully closed.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Utilize pressure gauges to determine if PS2 is outputting full supply pressure and exhausting all output pressure.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>-For single-acting (one air pipeline to the actuator)<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">One end-stop position should show full supply pressure. The other end-stop position will show zero pressure.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>-For double-acting (two air pipelines to the actuator)<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">One end-stop position should show full supply pressure, while the other gauge should show zero pressure. Output pressures will be reversed when driving the valve to another end-stop position, see the following example of double-acting pressure gauges at each end-stop position.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"gauges 2\" decoding=\"async\" height=\"227\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/gauges-2.jpg\" width=\"210\" \/><\/span><\/span><\/figure>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If PS2 can output full supply and exhaust in both directions, then something else is preventing the actuator from fully sealing to the valve seat.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Verify supply pressure is properly set.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If the process is still leaking through the valve, check the actuator\/valve for:<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Mechanical binding<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Valve seat wear<\/span><\/span><\/p>\n\n<h3 id=\"7_Change_in_Tuning_Parameters\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">7 Change in Tuning Parameters<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overshoot\/undershoot<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too fast<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The SIPART PS2 uses a control method called “pulse width modulation”. This is a true digital control method, where piezo valves, similar to very small solenoid valves, are used to control loading and exhausting air, to and from the positioner. As such, the tuning parameters listed below are based upon this control method.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Adjustable Tuning Parameters Descriptions:<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">[IMPUP] & [IMPDN]: Impulse Length UP and DOWN<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-These tuning parameters are similar to gain. They represent the minimum time the piezo valves will cycle; units are in milliseconds- ms. For example; if the value is 10 ms, the fastest the piezo valves will cycle is 10 ms, not any faster. Therefore, an increase in these values will increase the gain response. The range is 2.0 to 160 ms.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">[SSUP] & [SSDN]: Short Step Zone<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">These tuning parameters are similar to integral action. Essentially there are two actions of the piezo valves- long pulses and quick\/short pulses. The values are in percent of total stroke. When the position of the valve is within this Short Step Zone of the setpoint value, the positioner will begin the short pulses of the piezo valves. For example, if the current short step zone is 10 % and the positioner is given a step change from 0 to 50 %, the piezo valves are held wide open (long pulse) until the valve gets to within 10 % of the setpoint. Therefore, once the valve is at 40 %, the piezo valves will produce short\/quick pulses, to prevent overshoots. The smaller the value, the faster the response.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">[PRUP] & [PRDN]: Prediction Up and Down<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-These tuning parameters are similar to derivatives. This predicts the movement of the valve. The smaller the number, the less prediction is used, thus faster response. The range is 1 to 40.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>How to customize tuning parameters:<\/strong><\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Enter Diagnostic Mode:<\/strong><\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-When the device is in Auto mode, press and hold all three buttons down at the same time:<img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/><img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/><img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Diagnostic name is shown in the lower right of the display.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Edit Tuning Value:<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Go to the desired diagnostic parameter by pressing and releasing button. This will advance through the diagnostic menu.<br \/>\nTo go backward in the menu: While pressing and holding <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button, press and release <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Once at the desired tuning parameter: Press and hold <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>button until the number starts to change.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Use <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons to achieve desired tuning value.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Exit Diagnostic Mode:<\/strong><\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Press and hold <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until display changes.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-If the unit is in Manual mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button once to go to Auto mode.<\/span><\/span><\/p>\n\n<h3 id=\"8_Deadband_Too_Large\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">8 Deadband Too Large<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Drifts off setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overshoot\/undershoot<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Not responding input<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The deadband of the PS2 is the area around setpoint when the PS2 stops working to get closer to setpoint. For example, if the deadband value is 0.5 %, and the setpoint is 70 %, the PS2 will work the piezo valves to get within the following position range: 69.5 to 70.5 %. If the deadband is too large, the PS2 may not achieve the desired position.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">There are two settings for the PS2 Deadband: Auto or a fixed numerical value.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When configuration parameter “DEBA” = “Auto”, the deadband value is dynamic and changes per process conditions.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When configuration parameter “DEBA” is a fixed numerical value, the PS2 will always move the valve to get within this range of the setpoint.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The current deadband value can be viewed in diagnostic mode:<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-While in automatic mode, press all three buttons down at the same time for 5 seconds.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until diagnostic parameter “DBUP” or “DBDN” is shown.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-These diagnostic parameters show the current deadband value for up and down valve<br \/>\ndirections.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If deadband value is too large for the application, the PS2 is compensating to prevent valve oscillations. These valve oscillations could be:<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Too many steps change from the process controller. This is a process control loop issue. Discuss the issue with the operator and\/or plant process engineer.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Change Deadband Setting:<\/strong><\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">From AUT or MAN mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds. Now observe the parameter name in the lower right corner.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Continue to press the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until “DEBA” parameter is reached.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons to decrease deadband value.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To return to Automatic mode, press and hold the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The unit will now be in Manual mode.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button one time to return to Automatic mode.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"9_Deadband_Too_Small\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">9 Deadband Too Small<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The deadband of the PS2 is the area around the setpoint when the PS2 stops working to get closer to setpoint. For example, if the deadband value is 0.1 %, and the setpoint is 70 %, the PS2 will work the piezo valves to get within the following position range: 69.9 % to 70.1 %. Thus, the PS2 will continuously work to get within this deadband range. However, if the mechanics of the actuator and\/or valve cannot achieve this precise position, the PS2 will continuously hunt or oscillate around the setpoint position.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">There are two settings for the PS2 deadband: “Auto” or a fixed numerical value<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When configuration parameter “DEBA” = “Auto”, the deadband value is dynamic and changes per the process conditions. In other words, the deadband value changes if stiction or oscillation is detected. For example, the deadband value will increase when mechanical issues are detected. Additionally, the PS2 will periodically decrease the deadband value to try and achieve precise valve positioning. The deadband value changes in 0.1 % increments.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Thus, only a fixed deadband value can be too small.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Too small a deadband can cause valve oscillation and indicate.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Change Deadband Setting:<\/strong><\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">From AUT or MAN mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds. Now observe the parameter name in the lower right corner.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Continue to press the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until “DEBA” parameter is reached.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or<img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/> buttons to decrease deadband value or change to “Auto”.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To return to Automatic mode, press and hold the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The unit will now be in Manual mode.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button one time to return to Automatic mode.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"_10_Erratic_Feedback\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"> <br \/>\n10 Erratic Feedback<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve position deviation<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The PS2 is providing a false and jumpy feedback signal, but the actual valve position is not moving.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>First, rule out field wiring and power supply:<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does the large number on the local display represent the jumpy and false signal read on the 4-20 mA feedback?<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>If No:<\/strong><\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use an independent power source and current meter to isolate the field wiring by powering up the feedback card locally.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-24 V DC positive connected to terminal 61.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Put meter in current mode and connect positive to terminal 62.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Connect the wire of the current meter to 24 V DC negative, according to the Wiring below.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"2 wire connection wiring\" decoding=\"async\" height=\"366\" loading=\"lazy\" sizes=\"(max-width: 625px) 100vw, 625px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring.jpg 833w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-300x176.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-768x450.jpg 768w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-600x352.jpg 600w\" width=\"625\" \/><\/span><\/span><\/figure>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If erratic feedback is gone, then the issue is with field wiring or the original power source.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>If Yes:<\/strong><\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Put PS2 in Manual mode: from Auto, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Move valve with <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If a false feedback signal is corrected by moving the valve, consider Non-Contacting technology.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If false feedback is still present when moving the valve, verify:<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Slide bar is in proper location:<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">First, unlock slide bar: see Transmission Ratio\/Slide (Page 49).<br \/>\nMove slide bar back and forth twice, then move slide bar to proper setup position (see following):<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– For rotary, slide bar = 90°.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– For linear valves with travel at 25 mm (1.0 inch) or less; slide bar = 33°.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– For linear valves with travel at 25 mm (1.0 inch) or more; slide bar = 90°<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Reinitialize PS2. See Initialization Procedure (Page 50).<\/span><\/span><\/p>\n\n<h3 id=\"11_Erratic_Input_Signal\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">11 Erratic Input Signal<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">There are two ways to identify if the input signal is causing the valve behavior. One is placing a current meter in series of the 4 to 20 mA loop. The other is using the PS2’s display as a current meter. This is found in diagnostic parameter “mA”.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">While the positioner is exhibiting the problem, verify unit is in Automatic mode.<\/span><\/span><\/li>\n<\/ul>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press and hold all three buttons for at least 5 seconds.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-The diagnostic parameter name can be found in the lower right corner.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press the to advance through the menu.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Go to Diagnostic parameter “mA”.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Observe the movement of the actuator\/valve and compare it to what is displayed on the PS2, or current meter. If the display is changing with the valve assembly, then the input signal is the cause. An investigation of the control system\/loop tuning is suggested.<\/span><\/span><\/p>\n\n<h3 id=\"12_High_Vibration\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">12 High Vibration<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve position deviation<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Too much vibration can cause erroneous feedback and damage the positioner. The SIPART PS2 vibration specifications are:<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Harmonic oscillations (sine-wave) according to EN 60068-2-6\/10.2008<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Bumping (half-sine) according to EN 60068-2-27\/02.2010<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Noise (digitally controlled) according to EN 60068-2-64\/04.2009<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Recommended continuous duty range of the complete fitting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If excessive vibration cannot be avoided, consider Non-Contacting technology. Contact Siemens technical support for assistance: 1-800-333-7421.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"13_Initialization_Incomplete\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">13 Initialization Incomplete<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Won’t calibrate<\/span><\/span><\/li>\n<\/ul>\n\n<figure>\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Fault Profile (symptoms)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Possible Cause(s)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Corrective Measures<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Positioner remains in”RUN 1″<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• Waiting time of 1 minute not accomplished.<br \/>\n\t\t\t• Loose or Worn Linkage (Page 29)<br \/>\n\t\t\t• Supply air not connected or Insufficient Supply Air (Page 28)<br \/>\n\t\t\t• Valve Block Failure (Page 38)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• A waiting time of 2 minutes<br \/>\n\t\t\tis essential. Start initialization from a mid-stroke position.<br \/>\n\t\t\t• See Loose or Worn Linkage(Page 29)<br \/>\n\t\t\t• See Insufficient Supply Air(Page 28)<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Positioner remains in<br \/>\n\t\t\t“RUN 2”<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• Transmission ratio selector and parameter “2. YAGL” is not set correctly and\/or real stroke does not match.<br \/>\n\t\t\t• Incorrectly set stroke on the lever.<br \/>\n\t\t\t• Valve Block issue, see Valve Block<br \/>\n\t\t\tFailure (Page 38)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• Initialization Procedure(Page 50)<br \/>\n\t\t\t• See “Possible Messages” table of Leaflet.<br \/>\n\t\t\t• If “Tolerance Band Down Violated” message, adjust slip-clutch as instructed in leaflet<\/span><\/span><\/td>\n\t\t<\/tr>\n\t<\/tbody>\n<\/table>\n<\/figure>\n\n<figure>\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Fault Profile (symptoms)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Possible Cause(s)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Corrective Measures<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Positioner remains in<br \/>\n\t\t\t“RUN 3”<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• Actuator travel time is too high.<br \/>\n\t\t\t• Air Leak (Page 16)<br \/>\n\t\t\t• Non-active zone is in the valve<br \/>\n\t\t\tstroke*. Non-active zone is in the<br \/>\n\t\t\tvalve stroke*, see Valve Block Failure (Page 38)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• Open the restrictor completely and\/or set the supply air to the highest permissible value see Insufficient Supply Air (Page 28)<br \/>\n\t\t\t• See Air Leak (Page 16)<br \/>\n\t\t\t• See star notation below.<br \/>\n\t\t\t• Use a booster if faster stroke times are desired.<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Positioner remains in<br \/>\n\t\t\t“RUN 4”<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• Air Leak (Page 16)<br \/>\n\t\t\t• Booster(s) Not Properly Tuned(Page 18)<br \/>\n\t\t\t• Loose or Worn Linkage (Page 29)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• See Air Leak (Page 16)<br \/>\n\t\t\t• See Booster(s) Not Properly Tuned (Page 18)<br \/>\n\t\t\t• See Loose or Worn Linkage (Page 29)<\/span><\/span><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The positioner remains<br \/>\n\t\t\tin “RUN5”, but does not go up to “FINISH”<br \/>\n\t\t\t(waiting time> 7 min).<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• Loose or Worn Linkage (Page 29)<br \/>\n\t\t\t• Booster(s) Not Properly Tuned (Page 18)<br \/>\n\t\t\t• Air Leak (Page 16)<\/span><\/span><\/td>\n\t\t\t<td><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">• Part-turn actuator: verify coupling set screw is secure.<br \/>\n\t\t\t• Linear actuator: verify lever arm is secure to input shaft.<br \/>\n\t\t\t• Correct any slack between the actuator and valve.<br \/>\n\t\t\t• Loose or Worn Linkage (Page 29)<\/span><\/span><\/td>\n\t\t<\/tr>\n\t<\/tbody>\n<\/table>\n<\/figure>\n\n<h3 id=\"14_Insufficient_Supply_Air\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">14 Insufficient Supply Air<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Always going to alarm<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Not responding input<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not fully close\/open<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valva position deviation<\/span><\/span><\/li>\n<\/ul>\n\n<p> <\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Maximum air pressure ratings are displayed on the actuator’s nameplate\/stamp. Using too little air pressure will slow down the stroke times of the valve assembly. The PS2 positioner can handle up to 100 psi as long as the recommended actuator pressure is not exceeded.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Adjust supply pressure according to the application.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If pressure adjustments are made, run initialization. See Initialization Procedure(Page 50)<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"15_Loose_or_Worn_Linkage\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">15 Loose or Worn Linkage<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Won’t calibrate<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve is not repeatable<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Drifts off setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overshoot\/undershoot<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Doest not fully close\/open<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve position deviation<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">A valve positioner’s performance is directly dependent upon its mechanical connection to the actuator. For example, if the mechanical coupling is loose or worn on the positioner’s input shaft, valve performance will suffer.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Identify loose or worn linkage as follows:<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">A loose input shaft can quickly be determined by moving the PS2’s slip clutch. See item #6 of Transmission Ratio\/Slide Bar (Page 49). The slip clutch should not rotate without clicking. The flameproof enclosure should rotate easily.<br \/>\n– Put PS2 in Manual mode from Auto press<img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/> button.<br \/>\nNote: NOINI mode can also be used.<br \/>\n– Using the <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons, move the valve back and forth in both directions.<br \/>\n– While the valve is moving back and forth inspect the movements of:<br \/>\n○ For Rotary: Actuator shaft, Positioner coupling and Positioner input shaft.<br \/>\n○ For Linear: Actuator shaft, Actuator stem coupling, Feedback pin, Feedback arm, and Positioner input shaft.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– All of these components must move in unison- all together.<br \/>\n○ Several back and forth movements will be necessary to identify the loose component.<\/span><\/span><\/p>\n\n<h3 id=\"16_Manual_Mode\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">16 Manual Mode<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Not responding input<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When bottom section of display shows: “MANxx” (xx = input signal), the unit is in Manual<br \/>\nmode. In Manual mode, the unit ignores setpoint command signal. It is possible to use the<br \/>\n<img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons to manually drive the actuator.<br \/>\n● To exit manual mode and allow control using a setpoint, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button one time.<br \/>\n– Unit will display: “AUTxx” (xx = input signal), in the lower right-hand corner when in<br \/>\nAutomatic mode.<\/span><\/span><\/p>\n\n<h3 id=\"17_Mechanical_Blockage\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">17 Mechanical Blockage<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve position deviation<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">While position deviation exists, determine which output pressure gauge is used to move the valve and eliminate the current deviation.<br \/>\n● If the output pressure is equal to supply pressure, then:<br \/>\n– Issue is not the PS2, check for mechanical blockage that is preventing valve movement. This could occur in the actuator and\/or valve, refer to the actuator\/valve service manual.<br \/>\n● If the output pressure is unable to reach full supply pressure, then:<br \/>\n– Issue is an air leak somewhere in the output; see Air Leak (Page 16).<br \/>\n● If output pressure is unable to exhaust, check the exhaust port for blockage; otherwise, replace the piezo block.<br \/>\n● If PS2 is satisfied with the current position deviation, the deadband could be too large.<\/span><\/span><\/p>\n\n<h3 id=\"18_Parameter_1YFCT\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">18 Parameter 1.YFCT<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is backward<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overshoot\/undershoot<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve position deviation<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The actual valve position does not match the PS2 display<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The two most common options for parameter 1 are WAY and TURN. “WAY” is for linear actuators which will have feedback arm\/linkage connecting the positioner to the actuator.<br \/>\n“TURN” is for rotary actuators which have a direct coupling connecting the positioner to the actuator.<br \/>\nFirmware version 5.00.00 and newer will have a normal and inverted actuator type for all Parameter 1 options. Inverted selections are identified with a minus sign. Normal and inverted refers to the rotation of the PS2’s input shaft when the valve or damper closes.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use Normal:<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Part-turn actuator closes when the positioner shaft or NCS rotates in the clockwise direction.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Linear actuator closes when the actuator spindle moves downwards and the positioner shaft or NCS rotates in the anti-clockwise direction.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use Inverted, indicated with the minus symbol if valve moves in opposite direction as described above.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Turn\/-turn: For a part-turn actuator with a directly mounted positioner.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">WAY\/-WAY: For a linear actuator with a carrier pin mounted on the lever.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">FWAY\/-FWAY: For a linear actuator with a carrier pin mounted on the actuator spindle.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">LWAY\/-LWAY: For an external linear potentiometer on a linear actuator.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">ncSt\/-ncSt: For an NCS sensor (6DR4004-.N.10 and -.N.40) on a part-turn actuator, and for an internal NCS module.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">ncSL\/-ncSL: For an NCS sensor (6DR4004-.N.20) on a linear actuator for strokes < 14 mm (0.55 inch).<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">ncSLL\/-ncLL: For an NCS sensor (6DR4004-.N.30) on a linear actuator for strokes >14 mm (0.55 inch) and for an internal NCS module.<\/span><\/span><\/li>\n<\/ul>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"ps2 positioner for rotary application\" decoding=\"async\" height=\"307\" loading=\"lazy\" sizes=\"(max-width: 626px) 100vw, 626px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-rotary-application.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-rotary-application.jpg 626w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-rotary-application-300x147.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-rotary-application-600x294.jpg 600w\" width=\"626\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">ps2 positioner for rotary application<\/span><\/span><\/figcaption>\n<\/figure>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"ps2 positioner for linear application\" decoding=\"async\" height=\"446\" loading=\"lazy\" sizes=\"(max-width: 801px) 100vw, 801px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-linear-application.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-linear-application.jpg 801w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-linear-application-300x167.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-linear-application-768x428.jpg 768w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/PS2-positioner-for-linear-application-600x334.jpg 600w\" width=\"801\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">ps2 positioner for linear application<\/span><\/span><\/figcaption>\n<\/figure>\n\n<h3 id=\"19_Parameter_6SCUR\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">19 Parameter 6.SCUR<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve goes to 20% position with 4mA setpoint<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Default setting is: “4 mA”.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">From AUT or MAN mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds. Now observe the parameter name in the lower right corner.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Continue to press the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until “SCUR” parameter is reached.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If it says “0 mA”, press the button to change this to “4 mA”.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To return to Automatic mode, press and hold the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The unit will now be in Manual mode.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button one time to return to Automatic mode.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"20_Re-Initialization_Positioner_\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">20 Re-Initialization Positioner <\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The actual valve position does not match the PS2 display<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"21_Reversing_the_Action\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">21 Reversing the Action<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is backward<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">There are two ways to invert the action and display, one requires re-initialization.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>No re-initialization procedure<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">This procedure inverts the physical action and display of the positioner.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Parameter “SDIR” reverses the physical action<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-From AUT or MAN mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds. Observe parameter name in the lower right corner.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-Continue to press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until “SDIR” Parameter is reached.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">-If “SDIR” Parameter displays “riSE” change to “FALL” or vice versa.<br \/>\nUse <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons to change option.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">“YDIR” Parameter reverses the display and feedback signal.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Continue to press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until “YDIR” Parameter is reached.<br \/>\n– If “YDIR” Parameter displays “riSE” change to “FALL” or vice versa.<br \/>\nUse <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons to change option.<br \/>\n– To return to Automatic mode, press and hold <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds. The unit will<br \/>\nnow be in Manual mode.<br \/>\n– Press<img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/> button one time to return to Automatic mode.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Note: If using the alarm card and\/or advance diagnostics, the alarm thresholds values may not match actual valve position. To correct this, use the following procedure to reverse the action.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Re-initialization Procedure (Firmware 5.00.00 or greater)<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Firmware number is printed on PS2 nameplate. Also, the display flashes firmware number when exiting configuration mode.<br \/>\nChange Parameter 1 to the inverse functions:<br \/>\n● From AUT or MAN mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds. Observe number in the lower<br \/>\nleft hand corner.<br \/>\n● Continue to press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until Parameter 1 is reached.<br \/>\n● Change parameter 1 value to its inverse. For example change “turn” to “-turn”.<br \/>\n● When Parameter 1 is changed, the unit must be re-initialized.<\/span><\/span><\/p>\n\n<h3 id=\"22_Setpoint_Ramping\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">22 Setpoint Ramping<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The setpoint ramp is only effective in Automatic mode. This parameter changes the positioner’s speed of response. Essentially, this slows down the valve travel times. To achieve the fastest times, these parameters should be set to a value of zero.<br \/>\n● From Manual or Automatic mode press and hold button for 5 seconds to enter configuration menu.<br \/>\n– Pressing the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>will advance through the parameters.<br \/>\n● Go to parameter “TSUP” and “TSDO”.<br \/>\n– Use the <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and\/or <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button to change the values.<br \/>\n● To return to Automatic mode, press and hold <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds.<br \/>\n– The unit will now be in Manual mode.<br \/>\n● Press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button once to return to Automatic mode.<\/span><\/span><\/p>\n\n<h3 id=\"23_Stays_at_20_mA_Position\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">23 Stays at 20 mA Position<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Not responding input<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">When PS2 is in automatic or manual mode, the input signal is shown in the lower right corner of the display. This value is in percent and should change with a change in the input signal.<br \/>\nUse PS2 diagnostic number “mA” to convert the display to the current meter.<br \/>\n● From automatic mode or manual mode, press all three buttons down at the same time for<br \/>\n5 seconds.<br \/>\n● Press and release <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button and go to diagnostic parameter “mA.”<br \/>\n● The display will show input signal in milliamps.<br \/>\nIf milliamp is approximately fixed to 22.0 mA, this indicates the board was or still is<br \/>\nimproperly powered.<br \/>\n● To exit Diagnostic mode press and hold <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until display changes.<br \/>\nFor 2-wire loop power, the power supply must be a regulated current source. A current<br \/>\nsource regulates current.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Note<br \/>\nA voltage source does not regulate current, the circuit’s resistance does. Therefore if the circuit’s resistance is low, the current can be too high and damage the PS2 board.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Resolve power issue and replace PS2 circuit board. Board part numbers can be found in PS2 Operating Instructions P\/N#: A5E00074631, or contact Siemens.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If milliamp changes with the input signal, check PS2 configuration.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To restore all PS2 parameters to factory setting:<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– From Auto\/Manual mode, press and hold button until display changes.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Press and release button and go to “PRST” parameter.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">– Press and hold button until display shows: “OCAY”<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Set configuration parameters as per the application and re-initialize PS2,<\/span><\/span><\/p>\n\n<h3 id=\"24_Stiction\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">24 Stiction<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve is not repeatable<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overshoot\/undershoot<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Always going to alarm<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Not responding input<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not fully close\/open<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve position deviation<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">This term is used to identify the friction that exists in a valve assembly that prevents smooth stem motion. An example is an initial friction that exists when pushing a heavy box across the floor- first, the pushing force must overcome the friction before the box will move.<br \/>\nIf stiction is too great in a valve assembly, then the valve is unable to achieve small valve movements, such as 0.1 %.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To identify this symptom:<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Put PS2 in Manual mode- from Auto press button once.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">While using the and\/or buttons try to move valve assembly in the smallest movements, for example, 0.2 % movements.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If the valve assembly cannot achieve these small movements manually, then there is too<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">much stiction.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The way to quantify how much stiction exists is by how little the valve can move. For example, if the smallest movement that can be achieved is 0.8 %, then this is the best the valve assembly can move- in 0.8% increments. Therefore trying to achieve smaller movements is impossible and will result in oscillations.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillations can be reduced by setting the Deadband value to “Auto”<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"25_Supply_Air_Too_High\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">25 Supply Air Too High<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Oscillation\/hunting<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too fast<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Maximum air pressure ratings are indicated on the actuator’s nameplate\/stamp. Using too much air pressure can inhibit performance and could damage the actuator and\/or positioner. The PS2 positioner can handle up to 100 psi as long as the recommended actuator pressure is not exceeded.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">● Adjust supply pressure according to the application.<br \/>\n● If adjustments are made, run the initialization process<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">High supply pressure can cause quick valve responses, and lead to overshoots, oscillations, and incomplete initialization. If high supply pressure is required for application, the minimum travel time may not be met. The PS2 requires at least 1.0 second of travel time for each valve direction. If PS2 has been initialized, travel times can be found in Diagnostic menu:<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">From Auto or Manual modes, press all three buttons down for 5 seconds.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Diagnostic name will be shown in lower right of display.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until “TUP” and TDOWN” are shown.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If travel times are faster than 1 second, reduce valve travel speed with built-in flow restrictor\/s see Device Identification section 1.4, items 6, 7 and 8:<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">During RUN 3 of initialization process, the display will flash with valve travel times.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button while times are flashing on display.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Display will show “NOZZL”. Adjust built-in flow restrictor\/s in clockwise direction with appropriate Allen key.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button again and PS2 will fully stroke the valve and update the display with the current travel times.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If minimum travel times are not met, at least 1 second for both directions, then press <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button again while display is flashing travel times.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Adjust built-in flow restrictor\/s clockwise to restrict more flow to and from actuator.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Press <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button and repeat as necessary. If desired travel times are met, do not push any buttons and PS2 will complete initialization process.<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"26_Too_Much_Restriction\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">26 Too Much Restriction<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To achieve the fastest possible stroke times, verify the restrictor screws are in their factory position which is all the way open. See photo for the actual position.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If there are any issues with response\/stroke times, then open the restrictor(s) by turning counter-clockwise until the factory position is reached.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If restrictor screws were adjusted, a new initialization needs to be performed.<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"restrictor of valve positioner\" decoding=\"async\" height=\"228\" loading=\"lazy\" sizes=\"(max-width: 642px) 100vw, 642px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/restrictor-of-valve-positioner.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/restrictor-of-valve-positioner.jpg 642w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/restrictor-of-valve-positioner-300x107.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/restrictor-of-valve-positioner-600x213.jpg 600w\" width=\"642\" \/><\/span><\/span><\/figure>\n\n<h3 id=\"27_Tubing_Lines_Configuration\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">27 Tubing Lines Configuration<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is backward<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"28_Unit_Not_Initialized\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">28 Unit Not Initialized<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">NOINI on display<\/span><\/span><\/li>\n<\/ul>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><a href=\"https:\/\/cncontrolvalve.com\/what-is-the-difference-between-a-pressure-control-valve-and-a-flow-control-valve\/\"><img alt=\"dn350 pressure control valve 14inches\" decoding=\"async\" height=\"576\" loading=\"lazy\" sizes=\"(max-width: 768px) 100vw, 768px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/DN350-pressure-control-valve-14inches-1024x768.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/DN350-pressure-control-valve-14inches-1024x768.jpg 1024w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/DN350-pressure-control-valve-14inches-300x225.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/DN350-pressure-control-valve-14inches-768x576.jpg 768w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/DN350-pressure-control-valve-14inches-1536x1152.jpg 1536w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/DN350-pressure-control-valve-14inches-600x450.jpg 600w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/DN350-pressure-control-valve-14inches.jpg 1706w\" width=\"768\" \/><\/a><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">dn350 pressure control valve 14inches<\/span><\/span><\/figcaption>\n<\/figure>\n\n<h3 id=\"29_Valve_Block_Failure\"><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">29 Valve Block Failure<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve action is too slow<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Won’t calibrate<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Drifts off setpoint<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not fully close\/open<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Error code 1<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not get to setpoint<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve block failure can occur for several reasons. The most common failure is a result of poor air quality, which can include moisture. In addition to an air drying system, it is recommended to install a coalescent filter on the supply line, directly upstream of the positioner. Siemens offers an Air Coalescing Filter, Model 2306, which removes dirt, oil, moisture, and other impurities from the instrument-air supply.<br \/>\nIn addition, exceeding the recommended supply pressure will damage the valve block. The maximum pressure rating for the PS2 is: 101 psi (7 bar), see Supply Air Too High (Page 50).<br \/>\nIt is recommended to install a regulator on the supply line, upstream from the positioner, and to regulate supply pressure so it does not exceed the maximum pressure rating of the PS2 and the actuator. Siemens offers a filter regulator, Model 91H, which regulates pressure and removes debris.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Valve Block Testing<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The following tests will refer to gauges on the supply and output(s) of pneumatic lines. If the PS2 does not have a gauge block, consider temporary gauge installation (inline) for diagnostic purposes. Pipe plugs may also be needed; either ¼ inch NPT or G¼ thread.<br \/>\nVerify pneumatic port thread type before inserting pipe plugs – refer to model code and SIPART PS2 catalog sheet.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Activate NOINI Mode (if not already activated)<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Enter configuration mode and go to parameter: “4.INITA”.<br \/>\n– From AUT or MAN mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds.<br \/>\n– Parameter number will be displayed in lower left-hand corner.<br \/>\n– Press and release <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button and go to parameter “4.INITA”.<br \/>\n– Once at parameter “4.INITA”, press and hold<img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/> button until display changes to: “no”.<br \/>\n– Press and hold <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds to exit configuration mode.<br \/>\n– Display should flash “noini” in the lower right.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Use Two-Button Method to Simulate Movement<\/strong><\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">While pressing and holding the button, press and hold the button.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To move the valve assembly in the opposite direction, reverse the two push-button sequences. Use the two-button method and observe pressure changes on each output gauge.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Single-acting – In one direction the output gauge should reach full supply pressure and hold when the buttons are released. When going in the opposite direction, the output gauge should go to zero psi. While it is going to zero, air pressure should be blowing out of the exhaust port.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Double-acting – The two output gauges will indicate opposite pressures from each other, when at each end-stop position. While the top gauge is pressurizing the bottom gauge should be exhausting. The gauge that is pressurizing should reach full supply and hold when the buttons are released. The device should only exhaust while the unit is moving. At rest, no air should be blowing out of the exhaust port.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Makrolon Enclosure & Flameproof Enclosure<\/span><\/span><\/p>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"makrolon enclosure flameproof enclosure\" decoding=\"async\" height=\"278\" loading=\"lazy\" sizes=\"(max-width: 736px) 100vw, 736px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/Makrolon-Enclosure-Flameproof-Enclosure.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/Makrolon-Enclosure-Flameproof-Enclosure.jpg 736w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/Makrolon-Enclosure-Flameproof-Enclosure-300x113.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/Makrolon-Enclosure-Flameproof-Enclosure-600x227.jpg 600w\" width=\"736\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Makrolon enclosure flameproof enclosure<\/span><\/span><\/figcaption>\n<\/figure>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">If PS2 can output full supply pressure and fully exhaust, then something else is preventing actuator from fully closing or opening. Check valve assembly for mechanical blockage and air leaks. Also verify supply is at required pressure for application.<br \/>\n● If possible, drive actuator\/valve to a mid-travel position (50 %). Does air pressure hold<br \/>\nwhen the buttons are released?<br \/>\n– If yes, the valve block\/PS2 is working correctly.<br \/>\n– If not, check for leaks and perform the Pipe Plug Test at the end of this section.<br \/>\n● Does the unit exhaust?<br \/>\n– For double-acting, the unit should always exhaust during movement. For single-acting, the unit will only exhaust in one direction.<br \/>\n– If one of the output ports does not exhaust, check exhaust port for blockage.<br \/>\n○ If exhaust port is free from blockage, go to Pipe Plug Test at the end of this section.<br \/>\n– If unit always exhausts, verify parameter “PNEUM” is set correctly.<br \/>\n○ “Std” = Standard Valve Block or “FIP” = Fail in Place Valve Block (“F01” at end of the model code indicates FIP option).<br \/>\n○ If this is set correctly, go to the Pipe Plug Test.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Pipe Plug Test<\/strong><\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Turn off supply air to PS2.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Slowly remove pneumatic connections from the output port(s) on the positioner.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Install appropriate thread type pipe plug into each output port(s). The only pneumatic line connected to the PS2 should be supplied. See photo below.<\/span><\/span><\/li>\n<\/ul>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"output of positioner\" decoding=\"async\" height=\"345\" loading=\"lazy\" sizes=\"(max-width: 467px) 100vw, 467px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/output-of-positioner.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/output-of-positioner.jpg 467w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/output-of-positioner-300x222.jpg 300w\" width=\"467\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">output of positioner<\/span><\/span><\/figcaption>\n<\/figure>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Use the two-button method to pressurize the output chamber.<br \/>\n– Repeat this in both directions.<br \/>\nIf PS2 can output full supply and fully exhaust, then something else is preventing the actuator from fully closing or opening. Check valve assembly for mechanical blockage and air leaks.<br \/>\nAlso verify supply is at required pressure for application.<br \/>\n● If PS2 does not exhaust pressure from one of the output ports, replace the valve block.<br \/>\n● If the unit does not hold pressure when buttons are released, check for leaks around pipe plug(s), gauge manifold block and PS2 pneumatic connection block (this is a black anodized aluminum block directly against PS2 enclosure).<br \/>\n– If no leaks are found, replace the valve block.<br \/>\nReplacement Part Numbers<br \/>\nPneumatic single-acting piezo block kit: C73451-A430-D80<br \/>\nPneumatic double-acting piezo block kit: C73451-A430-D81<br \/>\nEach kit includes a Valve block, O-ring, and Screws.<\/span><\/span><\/p>\n\n<p><br \/>\n<span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">30 Valve Does Not Go Fully Closed\/Open<\/span><\/span><\/p>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Does not fully close\/open<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">From AUT or MAN mode, press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds.<br \/>\n– Observer parameter name in the lower left hand corner.<br \/>\n● Continue to press <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button until “YCLS” Parameter is reached.<br \/>\n– Note: While in configuration mode, the positioner is NOT controlling the valve.<br \/>\n● Use <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>and <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>buttons to change Parameter values:<br \/>\n– Set Parameter YCLS to “Up do” (Tight Closing Up and Down)<br \/>\n● To exit configuration mode, press and hold <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button for 5 seconds.<br \/>\n– Unit should be in Manual Mode.<br \/>\n● Press and release <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button once to enter AUTO mode.<br \/>\n● Verify the valve assembly goes to the fully open and\/or closed position with a 0 or 100%<br \/>\ncommand signal.<br \/>\n● If not:<br \/>\n– The problem may be the input signal. Use the PS2’s display as a current meter. This is found in the Diagnostic parameter “mA”.<br \/>\n– Verify unit is in Automatic mode.<br \/>\n– Provide a 4 mA input signal.<br \/>\n– Press all three buttons down until display changes.<br \/>\n○ Diagnostic menu will be displayed. The diagnostic name can be found in the lower<br \/>\nright corner.<br \/>\n● Press the <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button to advance through the menu.<br \/>\n– While pressing and holding <img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/>button, press the <img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/>button to go backwards in menu.<br \/>\n● Go to option “mA”.<br \/>\n● Observe display and verify if the positioner is actually displaying ≈ 4 mA. If not, then the<br \/>\ninput signal is the cause.<br \/>\n● To exit diagnostic mode, press and hold<img alt=\"button1\" decoding=\"async\" height=\"36\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button1.jpg\" width=\"38\" \/> button for 5 seconds.<\/span><\/span><\/p>\n\n<h3 id=\"31_Wiring\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">31 Wiring<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Symptoms<\/span><\/span><\/h4>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">No display<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">No 4-20mA feedback<\/span><\/span><\/li>\n<\/ul>\n\n<h3 id=\"2-Wire_Connection_Wiring_For_Siemens_Positioner\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">2-Wire Connection Wiring For Siemens Positioner<\/span><\/span><\/h3>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"2 wire connection wiring\" decoding=\"async\" height=\"488\" loading=\"lazy\" sizes=\"(max-width: 833px) 100vw, 833px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring.jpg 833w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-300x176.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-768x450.jpg 768w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-600x352.jpg 600w\" width=\"833\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">2 wire connection wiring<\/span><\/span><\/figcaption>\n<\/figure>\n\n<h3 id=\"2-Wire_Connection_Wiring_of_PS2_Positioner\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">2-Wire Connection Wiring of PS2 Positioner<\/span><\/span><\/h3>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"2 wire connection wiring of ps2 positioner\" decoding=\"async\" height=\"339\" loading=\"lazy\" sizes=\"(max-width: 698px) 100vw, 698px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-of-PS2-positioner.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-of-PS2-positioner.jpg 698w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-of-PS2-positioner-300x146.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/2-wire-connection-wiring-of-PS2-positioner-600x291.jpg 600w\" width=\"698\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">2 wire connection wiring of ps2 positioner<\/span><\/span><\/figcaption>\n<\/figure>\n\n<h3 id=\"4_to_20_mA_Feedback_Module_Wiring_of_PS2_positioner\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">4 to 20 mA Feedback Module Wiring of PS2 positioner<\/span><\/span><\/h3>\n\n<figure><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><img alt=\"4 to 20 ma feedback module wiring of ps2 positioner\" decoding=\"async\" height=\"444\" loading=\"lazy\" sizes=\"(max-width: 764px) 100vw, 764px\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/4-to-20-mA-Feedback-Module-wiring-of-PS2-positioner.jpg\" srcset=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/4-to-20-mA-Feedback-Module-wiring-of-PS2-positioner.jpg 764w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/4-to-20-mA-Feedback-Module-wiring-of-PS2-positioner-300x174.jpg 300w, https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/4-to-20-mA-Feedback-Module-wiring-of-PS2-positioner-600x349.jpg 600w\" width=\"764\" \/><\/span><\/span>\n\n<figcaption><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">4 to 20 ma feedback module wiring of ps2 positioner<\/span><\/span><\/figcaption>\n<\/figure>\n\n<p> <\/p>\n\n<h2 id=\"Troubleshooting_SIPART_PS2_Siemens_Digital_Positioner_For_Control_Valves\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Troubleshooting SIPART PS2 Siemens Digital Positioner For Control Valves<\/span><\/span><\/h2>\n\n<p> <\/p>\n\n<h3 id=\"Case_1_Control_valve_can_not_be_fully_closed\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 1: Control valve can not be fully closed<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">In the process production, due to plug wear or large differential pressure, the control valve may not be tight shutoff, and it will cause leakage that affects the process operation. You can set parameters 39YCLS, 40YCD, 41YCU, and other items to enable the tight shutdown function, the control valve will be closed as much as possible. In chemical production, process operators often describe that the control valve can’t be closed and there is a large leakage, which affects the operation, we can use this function to meet the needs of the process as much as possible without replacing the control valve.<\/span><\/span><\/p>\n\n<h3 id=\"Case_2_The_flow_curve_of_the_control_valve_is_not_ideal\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 2: The flow curve of the control valve is not ideal<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">SIPART PS2 valve positioner parameter 12SFCT item, built-in six common <a data-id=\"https:\/\/cncontrolvalve.com\/why-do-different-control-valves-have-different-characteristics\/\" data-type=\"URL\" href=\"https:\/\/cncontrolvalve.com\/why-do-different-control-valves-have-different-characteristics\/\">flow characteristics<\/a> of control valves and user-defined flow characteristics, each control valve has its inherent flow characteristics, usually, this parameter of the positioner can follow the inherent flow characteristics of the control valve as long as it is set to Lin. If the flow characteristics of the control valve do not match the process requirements, the overall flow characteristics of the control valve can be changed through the setting of parameter 12SFCT. In short, the flexible setting of parameter 12SFCT can meet the process requirements according to the actual situation.<\/span><\/span><\/p>\n\n<h3 id=\"Case_3_Control_valve_action_direction_is_not_consistent_with_the_requirements\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 3: Control valve action direction is not consistent with the requirements<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">This is related to the setting of the two parameters 7SDIR and 38YDIR of the valve positioner. The 7SDIR item is the direction set point, and the setting of the 7SDIR item determines the lifting and lowering of the actuator when the positioner receives the 4~20mA signal.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The 38YDIR item is the travel direction display, which shows the lift of the actuator. By comparing with the actual switching direction of the control valve and the signal output from the control room, the parameter 7SDIR and parameter 38YDIR can be set correctly. when determining the switching direction of the control valve, it is necessary to cooperate with the process personnel, especially for the rotary type control valve, when the indication mark of the actuator is not clear, it is easy to misjudge the switching and cause production accidents, which must be taken seriously.<\/span><\/span><\/p>\n\n<h3 id=\"Case_4_Siemens_SIPARTPS2_positioner_initialization_stops_at_RUN5_and_does_not_reach_Finish_waiting_time_5min\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 4: Siemens SIPARTPS2 positioner initialization stops at RUN5 and does not reach Finish (waiting time >5min)<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The cause of this fault is the installation of the positioner, actuator, and other components. You can check the installation of the positioner, actuator, and feedback part, correct the problem in time, re-assemble it and then initialize it to see if the initialization time can be shortened<\/span><\/span><\/p>\n\n<h3 id=\"Case_5_Siemens_SIPARTPS2_positioner_stops_at_RUN3_during_initialization\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 5: Siemens SIPARTPS2 positioner stops at RUN3 during initialization<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The reason for this fault is that the actuator takes too long to position. We observe whether the actuator switching time can be reduced by opening the restrictor completely or adjusting the pressure PZ (air pressure) to the high allowed value. You can also use a booster to increase the actuator force and shorten the switching time.<\/span><\/span><\/p>\n\n<h3 id=\"_Case_6_When_Siemens_SIPARTPS2_positioner_initializes_it_stops_at_RUN2_and_cannot_proceed_\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 6: When Siemens SIPARTPS2 positioner initializes, it stops at RUN2 and cannot proceed<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Due to the high adaptive capability of the Siemens SIPARTPS2 positioner, it can work with linear and rotary type actuators with different travels. The positioner needs to set the parameters corresponding to the stroke during initialization so that the potentiometer detects the displacement of the actuator and the positioner drives the actuator action according to this displacement signal. If it stops at RUN2 during initialization, it is possible that the parameter setting is not reasonable. You can change the feedback shaft rotation angle in parameter 2YAGL of the valve positioner, changing 33° to 90°, and then initialize it again to see if it is successful. If the rotation angle of the feedback shaft is smaller than the small rotation angle, the initialization will not be successful. The feedback shaft rotation angle can be set as follows: set 33° when the stroke of the linear actuator is less than 20mm. Set 90° when the stroke of the linear actuator is more than 20mm. Set 90° automatically for the rotary type control valve.<\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">In addition, the stroke or angle of the actuator can also be adjusted manually. Manually adjusting the actuator stroke to the start and end positions can complete the step of RUN2. It is not necessary to automatically find the starting point of the actuator during the initialization of the positioner. So when automatic initialization is not possible, manual initialization is selected to enable the control valve to be adjusted.<\/span><\/span><\/p>\n\n<h3 id=\"Case_7_The_positioner_makes_a_sound_of_puffing_and_the_control_valve_produces_a_vibration\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 7: The positioner makes a sound of puffing, and the control valve produces a vibration<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">This is because of the positioner air tubing leakage, use soap water to detect the positioner outlet air pipeline and the connection of the actuator air source, find the leakage that the problem will be solved.<\/span><\/span><\/p>\n\n<h3 id=\"Case_8_Control_valve_maintenance_and_the_control_accuracy_has_problems\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 8: Control valve maintenance and the control accuracy has problems<\/span><\/span><\/h3>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">After maintenance of the control valve, due to changes in the positioner, valve stem, and feedback part, it must be initialized before the positioner and actuator can match each other and drive the actuator to act as a required control signal. The automatic initialization process of the Siemens SIPART PS2 valve positioner consists of five steps, which you can follow step by step for each task.<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 1, Determine whether the valve positioner is positive or negative actions and the LCD shows RUN1.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 2, determine the starting point and range of the valve positioner, the LCD will show RUN2.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 3, Determine the positioning time of the actuator, the LCD will show RUN3.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 4, determine the valve positioning increment value, the LCD shows RUN4.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Step 5, optimize the dynamic response of the actuator, and the LCD will display RUN5.<\/span><\/span><\/li>\n<\/ul>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">After completing the above five steps, the LCD will display Finish to complete the automatic initialization process and the valve positioner can work normally<\/span><\/span><\/p>\n\n<h3 id=\"Case_9_PS2_Smart_positioner_didn’t_work\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 9: PS2 Smart positioner didn’t work<\/span><\/span><\/h3>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Trouble Description: Single-acting valve positioner with HART function is used with a <a data-id=\"https:\/\/cncontrolvalve.com\/product-category\/butterfly-valves\/\" data-type=\"URL\" href=\"https:\/\/cncontrolvalve.com\/product-category\/butterfly-valves\/\">butterfly valve<\/a> (rotary type), the field failure is shown as when the input current signal is 15mA, the valve suddenly opens. When the input signal drops from 20mA to 16mA, the valve suddenly closes, and the valve functions similarly to a switching valve, which cannot play a control role according to different signal commands.<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>Troubleshooting<\/strong><\/span><\/span><\/p>\n\n<ol>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Access to the current signal and gas source, the fault state reappears (to confirm the fault).<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">In manual mode, press the up and down keys, and the valve moves normally.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Check the parameter setting is right.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Check that the diagnostic parameters and input current values are normal and that the positioner has been energized for 432 hours.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">In automatic mode, the positioner shows an unchanged opening value during input 4, 8, 12 to 15mA, and there is no input signal corresponding value % at the bottom right. When to 15mA, the instrumentation shows the valve opening value and the corresponding value % at the bottom right.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Remove the mainboard to observe that there is a clear layer of oil coating on the wiring board in the back area of the display, and clean the circuit board after obtaining consent.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Change the internal exhaust, to external exhaust, do restore settings, and re-initialize.<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Troubleshooting, the positioner works well<\/span><\/span><\/li>\n<\/ol>\n\n<figure> <\/figure>\n\n<h3 id=\"Case_10_Failure_caused_by_compressed_air_containing_water\"><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Case 10: Failure caused by compressed air containing water<\/span><\/span><\/h3>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Description: If the positioner inputs a 4-20mA signal, but the control valve does not act, first we need to switch the positioner to the manual mode, press the<img alt=\"button3\" decoding=\"async\" height=\"28\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button3.jpg\" width=\"30\" \/> key valve action, press the <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/> key, then the positioner display a black screen.<br \/>\nTreatment: disconnect the main board from the piezoelectric valve, and then press the “+” key, the main board of the positioner shows normal, it is obvious that the piezoelectric valve is a problem.<br \/>\nIf the piezoelectric valve is normal, the “+” key structure decomposition, clean up with alcohol, the positioner back to the normal, or piezoelectric valve is normal, “+” key decomposition after cleaning, still black screen, it is necessary to replace the motherboard.<\/span><\/span><\/p>\n\n<h4><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Solution:<\/span><\/span><\/h4>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">To make the mainboard and piezoelectric valve separate, and then press the <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>button, the positioner mainboard displays normal, which means the piezoelectric valve was damaged.<br \/>\nIf the piezoelectric valve is normal, the <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>button structure decomposition, clean up with alcohol, the positioner back to normal, or piezoelectric valve is normal, after cleaning <img alt=\"button2\" decoding=\"async\" height=\"32\" loading=\"lazy\" src=\"https:\/\/cncontrolvalve.com\/wp-content\/uploads\/2022\/06\/button2.jpg\" width=\"35\" \/>button, the display still black screen, it is necessary to replace the mainboard<\/span><\/span><\/p>\n","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/DAM%20CA%20MAU%202023\/ca%20mau%202023-2%281%29.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/DAM%20CA%20MAU%202023\/ca%20mau%202023-2%281%29.jpg","tags":["Calibration Fisher DVC6200 Positioner","Siemens SIPART PS2 Troubleshooting","Troubleshooting of Siemens SIPART PS2","Troubleshooting of Siemens SIPART PS2 Valve Positioner","Sipart Ps2 Positioner Calibration Procedure","Siemens PS2 Positioner Calibration","Siemens sipart ps2 calibration","Calibration SIPART PS2 Valve Positioner","Calibration the SIPART PS2 Valve Positioner","Ball Valve Hydrostatic test","Ball Valve Leak test","Bảo dưỡng sửa chữa van điều khiển","bảo dưỡng thiết bị","Bảo dưỡng van","bảo trì","bảo trì van điều khiển khí nén","Butterfly Control Valve Maintenance Services","Butterfly Valve Ball Valve Hydrostatic test","Check Valve Hydrostatic test","Check Valve Leak test","Control Valve Cablibration","Control Valve Calibration","Control valve calibration service","Control Valve Calibration Services","Control valve commissioning and testing","Control Valve Hydrostatic test","Control Valve Inspection","Control Valve Inspection and Calibration","Control valve inspection and testing","Control Valve Inspection Service","Control Valve Maintenance and Testing","Control Valve Maintenance Services","Control valve maintenance training","Control Valve Overhaul","Control valve overhaul training","Control valve pre-commissioning","Control Valve Repair","Control Valve Repair Serivce","Control Valve Seat Leak test","Control Valve Services","Control Valve Testing","Control Valve Testing Service","Dịch vụ bảo dưỡng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Cầu","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Mặt Bích Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van an toàn","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van Cổng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điện","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điều khiển","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van một chiều","Dịch vụ bảo trì sửa chữa van công nghiệp","Dịch vụ cân chỉnh van điều khiển","Dịch vụ đào tạo bảo dưỡng sửa chữa van điều khiển","Dịch vụ đào tạo bảo dưỡng van","Dịch vụ đào tạo hiệu chỉnh van điều khiển","Dịch vụ đào tạo loop check hệ thống điện","Dịch vụ đào tạo loop check hệ thống điều khiển","Dịch vụ đào tạo loop check van điều khiển","Dịch vụ đào tạo loop test hệ thống điện","Dịch vụ đào tạo loop test hệ thống điều khiển","Dịch vụ đào tạo loop test hệ thống điiều khiển","Dịch vụ đào tạo loop test van điều khiển","Dịch vụ đào tạo sửa chữa van","Dịch vụ đào tạo sửa chữa van điều khiển","Dịch vụ hiệu chuẩn van điều khiển","Dịch vụ hydrotest van","Dịch vụ mài rà mặt làm kín van","Dịch vụ mài rà van cổng","Dịch vụ mài rà van dao","Dịch vụ sửa chữa bảo dưỡng van điện","Dịch vụ sửa chữa bảo dưỡng van tay","Dịch vụ sửa chữa bảo dưỡng van thủy lực","Dịch vụ sửa chữa bộ điều khiển van","Dịch Vụ sửa chữa mặt làm kín van","DỊCH VỤ SỬA CHỮA TẤT CẢ CÁC LOẠI VAN","Dịch vụ sửa chữa van","Dịch vụ sửa chữa van bi","Dịch vụ sửa chữa van bướm","Dịch vụ sửa chữa van công nghiệp","Dịch vụ sửa chữa van một chiều","Dịch vụ thử áp đường ống","Dịch vụ thử áp hệ thống","Dịch vụ thử áp van điều khiển","Dịch vụ thử rò rỉ van điều khiển","Dịch vụ thử rò rỉ van tay","Dịch vụ thử rò van điều khiển","Dịch vụ thử thuỷ lực thân van","Dịch vụ thử thuỷ lực van điều khiển","Dịch vụ thử thuỷ lực van tay","Fucntion test control valves","Gate Valve Hydrostatic test","Gate Valve Leak test","Gate Valve Repair Serivce","Gia công mặt làm kín van","Globe Control Valve Maintenance Services","Globe Valve Hydrostatic test","Globe Valve Leak test","Hiệu chỉnh van điều khiển","Hiệu chuẩn van điều khiển","Hydrostatic test as per API 598","Hydrostatic test as per API 6D","lắp đặt van điều khiển khí nén","Manual valve hydrostatic test","Manual valve leak test","Manual Valve Repair Serivce","Manual valve testing","On-Off Valve Hydrostatic test","On-Off Valve Repair Serivce","On-Off Valve Seat Leak test","Overhaul Control Valves","phục hồi các loại van","Phun phủ kim loại","Phun phủ kim loại cho bề mặt của các chi tiết cơ khí","Phun phủ kim loại phục hồi bề mặt của các chi tiết cơ khí","Pneumatic actuator overhaul","Pneumatic actuator testing","Positioner repair","Pressure Safety Valve Calibration Service","Pressure Safety Valve Maintenance","Pressure Safety Valve Overhaul","Pressure Safety Valve Repair Serivce","Pressure Safety Valve Testing","Pressure Safety Valve Verification Service","PSV repair","PSV testing","PSV Verification","Repair control valves","Rotork actuator maintenance service","Samson control valves","Seat Leak test as per API 598","Seat Leak test as per FCI 70-2","Seat Leakage Test as per API 527","Sửa chữa","Sửa chữa kiểm định van an toàn","Sửa chữa mặt làm kín mặt bích","Sửa chữa mặt làm kín van","Sửa chữa van","Sửa chữa van an toàn","Sửa chữa van điều khiển","Sữa chữa van điều khiển Fisher","Sữa chữa van điều khiển Masoneilan","Sữa chữa van KOMOTO","Sửa chữa van KOSO","Sửa chữa van tay","thử nghiệm van điều khiển","Valve calibration Service","valve raise face lapping","valve raise face repair","Valve Services","Valve Surface lapping"],"count_view":4190,"seo_name":"troubleshooting-of-siemens-sipart-ps2-valve-positioners","date_update":1728532800,"date_created_format":1728824454,"meta_title":"Troubleshooting of Siemens SIPART PS2 Valve Positioner","meta_desc":"Troubleshooting of Siemens SIPART PS2 Valve Positioner","meta_keyword":"Calibration Fisher DVC6200 Positioner,Siemens SIPART PS2 Troubleshooting,Troubleshooting of Siemens SIPART PS2 ,Troubleshooting of Siemens SIPART PS2 Valve Positioner,Sipart Ps2 Positioner Calibration Procedure,Siemens PS2 Positioner Calibration,Siemens s","qr_code":"https:\/\/www.tkld-technical.com.vn\/troubleshooting-of-siemens-sipart-ps2-valve-positioners.html"},{"id":659895,"name":"Configuring and Calibration the SIPART PS2 Valve Positioners","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Hoặc : 0987056271- Mr. Kiếm<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:14px;\">Email: technical.manager@tkld.com.vn<\/span><\/span><\/p>\n","content":"<h1><strong><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Configuring and Calibration the SIPART PS2 Valve Positioner<\/span><\/span><\/strong><\/h1>\n\n<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">The SIPART PS2 is <b>the most widely used valve positioner for linear and part-turn actuators in industrial applications<\/b>. The all-round positioner of Siemens provides an extensive range of functions and is well equipped - even for extreme ambient conditions<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\"><a href=\"https:\/\/www.youtube.com\/watch?v=FNg0UUyGZC0\">https:\/\/www.youtube.com\/watch?v=FNg0UUyGZC0<\/a><\/span><\/span><\/p>\n","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/DAM%20CA%20MAU%202023\/ca%20mau%202023-2%281%29.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/DAM%20CA%20MAU%202023\/ca%20mau%202023-2%281%29.jpg","tags":["Sipart Ps2 Positioner Calibration Procedure","Siemens PS2 Positioner Calibration","Siemens sipart ps2 calibration","Calibration SIPART PS2 Valve Positioner","Calibration the SIPART PS2 Valve Positioner","Ball Valve Hydrostatic test","Ball Valve Leak test","Bảo dưỡng sửa chữa van điều khiển","bảo dưỡng thiết bị","Bảo dưỡng van","bảo trì","bảo trì van điều khiển khí nén","Butterfly Control Valve Maintenance Services","Butterfly Valve Ball Valve Hydrostatic test","Check Valve Hydrostatic test","Check Valve Leak test","Control Valve Cablibration","Control Valve Calibration","Control valve calibration service","Control Valve Calibration Services","Control valve commissioning and testing","Control Valve Hydrostatic test","Control Valve Inspection","Control Valve Inspection and Calibration","Control valve inspection and testing","Control Valve Inspection Service","Control Valve Maintenance and Testing","Control Valve Maintenance Services","Control valve maintenance training","Control Valve Overhaul","Control valve overhaul training","Control valve pre-commissioning","Control Valve Repair","Control Valve Repair Serivce","Control Valve Seat Leak test","Control Valve Services","Control Valve Testing","Control Valve Testing Service","Dịch vụ bảo dưỡng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Cầu","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Mặt Bích Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van an toàn","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van Cổng","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điện","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van điều khiển","Dịch Vụ Bảo Dưỡng Và Sửa Chữa Van một chiều","Dịch vụ bảo trì sửa chữa van công nghiệp","Dịch vụ cân chỉnh van điều khiển","Dịch vụ đào tạo bảo dưỡng sửa chữa van điều khiển","Dịch vụ đào tạo bảo dưỡng van","Dịch vụ đào tạo hiệu chỉnh van điều khiển","Dịch vụ đào tạo loop check hệ thống điện","Dịch vụ đào tạo loop check hệ thống điều khiển","Dịch vụ đào tạo loop check van điều khiển","Dịch vụ đào tạo loop test hệ thống điện","Dịch vụ đào tạo loop test hệ thống điều khiển","Dịch vụ đào tạo loop test hệ thống điiều khiển","Dịch vụ đào tạo loop test van điều khiển","Dịch vụ đào tạo sửa chữa van","Dịch vụ đào tạo sửa chữa van điều khiển","Dịch vụ hiệu chuẩn van điều khiển","Dịch vụ hydrotest van","Dịch vụ mài rà mặt làm kín van","Dịch vụ mài rà van cổng","Dịch vụ mài rà van dao","Dịch vụ sửa chữa bảo dưỡng van điện","Dịch vụ sửa chữa bảo dưỡng van tay","Dịch vụ sửa chữa bảo dưỡng van thủy lực","Dịch vụ sửa chữa bộ điều khiển van","Dịch Vụ sửa chữa mặt làm kín van","DỊCH VỤ SỬA CHỮA TẤT CẢ CÁC LOẠI VAN","Dịch vụ sửa chữa van","Dịch vụ sửa chữa van bi","Dịch vụ sửa chữa van bướm","Dịch vụ sửa chữa van công nghiệp","Dịch vụ sửa chữa van một chiều","Dịch vụ thử áp đường ống","Dịch vụ thử áp hệ thống","Dịch vụ thử áp van điều khiển","Dịch vụ thử rò rỉ van điều khiển","Dịch vụ thử rò rỉ van tay","Dịch vụ thử rò van điều khiển","Dịch vụ thử thuỷ lực thân van","Dịch vụ thử thuỷ lực van điều khiển","Dịch vụ thử thuỷ lực van tay","Fucntion test control valves","Gate Valve Hydrostatic test","Gate Valve Leak test","Gate Valve Repair Serivce","Gia công mặt làm kín van","Globe Control Valve Maintenance Services","Globe Valve Hydrostatic test","Globe Valve Leak test","Hiệu chỉnh van điều khiển","Hiệu chuẩn van điều khiển","Hydrostatic test as per API 598","Hydrostatic test as per API 6D","lắp đặt van điều khiển khí nén","Manual valve hydrostatic test","Manual valve leak test","Manual Valve Repair Serivce","Manual valve testing","On-Off Valve Hydrostatic test","On-Off Valve Repair Serivce","On-Off Valve Seat Leak test","Overhaul Control Valves","phục hồi các loại van","Phun phủ kim loại","Phun phủ kim loại cho bề mặt của các chi tiết cơ khí","Phun phủ kim loại phục hồi bề mặt của các chi tiết cơ khí","Pneumatic actuator overhaul","Pneumatic actuator testing","Positioner repair","Pressure Safety Valve Calibration Service","Pressure Safety Valve Maintenance","Pressure Safety Valve Overhaul","Pressure Safety Valve Repair Serivce","Pressure Safety Valve Testing","Pressure Safety Valve Verification Service","PSV repair","PSV testing","PSV Verification","Repair control valves","Rotork actuator maintenance service","Samson control valves","Seat Leak test as per API 598","Seat Leak test as per FCI 70-2","Seat Leakage Test as per API 527","Sửa chữa","Sửa chữa kiểm định van an toàn","Sửa chữa mặt làm kín mặt bích","Sửa chữa mặt làm kín van","Sửa chữa van","Sửa chữa van an toàn","Sửa chữa van điều khiển","Sữa chữa van điều khiển Fisher","Sữa chữa van điều khiển Masoneilan","Sữa chữa van KOMOTO","Sửa chữa van KOSO","Sửa chữa van tay","thử nghiệm van điều khiển","Valve calibration Service","valve raise face lapping","valve raise face repair","Valve Services","Valve Surface lapping"],"count_view":1384,"seo_name":"configuring-and-calibration-the-sipart-ps2-valve-positioners","date_update":1665374400,"date_created_format":1726373422,"meta_title":"Configuring and Calibration the SIPART PS2 Valve Positioner","meta_desc":"Configuring and Calibration the SIPART PS2 Valve Positioner","meta_keyword":"Sipart Ps2 Positioner Calibration Procedure,Siemens PS2 Positioner Calibration,Siemens sipart ps2 calibration,Calibration SIPART PS2 Valve Positioner,Calibration the SIPART PS2 Valve Positioner,Ball Valve Hydrostatic test, Ball Valve Leak test, Bảo dưỡng ","qr_code":"https:\/\/www.tkld-technical.com.vn\/configuring-and-calibration-the-sipart-ps2-valve-positioners.html"}]},"widget_6719888":{"content_data":{"content":"Danh mục Tin tức"}},"widget_6719892":{"content_data":{"content":"Tin tức mới"}},"widget_6796082":{"content_data":{"content":"Địa chỉ: 432\/16M2 Lê Đức Thọ, Phường 15, Quận Gò Vấp, Thành Phố Hồ Chí Minh"}},"widget_6796077":{"content_data":{"content":"<p><span style=\"font-size:16px\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/p>\n"}},"widget_6796214":{"content_data":{"content":"Hotline: +84-987 056 271<br>( Mr. Kiếm)"}},"widget_6796080":{"content_data":{"content":""}},"widget_6796085":{"content_data":{"content":"Email: info@tkld.com.vn"}},"widget_6796087":{"content_data":{"content":"Thông tin thêm"}},"widget_6796088":{"content_data":[{"id":54391,"name":"On-Off valve maintenance & calibration services","desc":"<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Phone\/Zalo\/WhatsApp: +84-987 056 271<\/span><\/span><\/p>\n\n<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Cù Hoàng Kiếm (Mr. Kevin)<\/span><\/span><\/p>\n\n<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n","content":"<p><strong><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">On-Off valve maintenance & calibration services<\/span><\/span><\/strong><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Capability of servicing valves up to 42”<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Gates, Globes, Check, Ball Butterfly, Plug valves and others<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Testing standards of API 598 and API 6 D<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Full Seat and Body Tests for valves up to 18” x 2500 lb Class. <\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Both Hydrostatic and Gas Tests capabilities with full safety barrier considerations<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Viewing of Tests via Video camera witnessing available<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Ball Valve Specialist reconditioning<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valve Repacking Services on site<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">In situ repair of high pressure welded On\/Off valves on line<\/span><\/span><\/li>\n<\/ul>\n\n<p><img src=\"\/datafiles\/40367\/upload\/images\/Pneumatic%20actuator.jpg\" style=\"width: 800px; height: 1067px;\" \/><\/p>\n\n<ul>\n<\/ul>\n\n<p> <\/p>\n","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/Control%20Valve%20Services\/Masoneilan%2020%20inch%20Anti%20surge%20valve.JPG","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/Control%20Valve%20Services\/Masoneilan%2020%20inch%20Anti%20surge%20valve.JPG","tags":"Control valve maintenance services,Control valve calibration services,Control valve maintenance and calibration services,Ball Valve Hydrostatic test, Ball Valve Leak test, Butterfly Control Valve Maintenance Services, Butterfly Valve Ball Valve Hydrostatic test, Check Valve Hydrostatic test, Check Valve Leak test, Control Valve Cablibration, Control Valve Calibration, Control valve calibration service, Control Valve Calibration Services, Control valve commissioning and testing, Control Valve Hydrostatic test, Control Valve Inspection, Control Valve Inspection and Calibration, Control valve inspection and testing, Control Valve Inspection Service, Control Valve Maintenance and Testing, Control Valve Maintenance Services, Control valve maintenance training, Control Valve Overhaul, Control valve overhaul training, Control valve pre-commissioning, Control Valve Repair, Control Valve Repair Serivce, Control Valve Seat Leak test, Control Valve Services, Control Valve Testing, Control Valve Testing Service, Fucntion test control valves, Gate Valve Hydrostatic test, Gate Valve Leak test, Gate Valve Repair Serivce, Gia công mặt làm kín van, Globe Control Valve Maintenance Services, Globe Valve Hydrostatic test, Globe Valve Leak test, Hydrostatic test as per API 598, Hydrostatic test as per API 6D, Manual valve hydrostatic test, Manual valve leak test, Manual Valve Repair Serivce, Manual valve testing, On-Off Valve Hydrostatic test, On-Off Valve Repair Serivce, On-Off Valve Seat Leak test, Overhaul Control Valves, Pneumatic actuator overhaul, Pneumatic actuator testing, Positioner repair, Pressure Safety Valve Calibration Service, Pressure Safety Valve Maintenance, Pressure Safety Valve Overhaul, Pressure Safety Valve Repair Serivce, Pressure Safety Valve Testing, Pressure Safety Valve Verification Service, PSV repair, PSV testing, PSV Verification, Repair control valves, Rotork actuator maintenance service, Samson control valves, Seat Leak test as per API 598, Seat Leak test as per FCI 70-2, Seat Leakage Test as per API 527,Valve calibration Service, valve raise face lapping, valve raise face repair, Valve Services, Valve Surface lapping","count_view":0,"seo_name":"on-off-valve-maintenance-calibration-services","date_update":0,"date_created_format":"1729947151","meta_title":"On-Off valve maintenance & calibration services","meta_desc":"On-Off valve maintenance & calibration services","meta_keyword":"Control valve maintenance services,Control valve calibration services,Control valve maintenance and calibration services,Ball Valve Hydrostatic test, Ball Valve Leak test, Bảo dưỡng sửa chữa van điều khiển, bảo dưỡng thiết bị, Bảo dưỡng van, bảo trì, bảo ","price":false,"price_final":false,"icon_svg":"","qr_code":"https:\/\/www.tkld-technical.com.vn\/on-off-valve-maintenance-calibration-services.html"},{"id":50419,"name":"Pressure switch calibration","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Phone\/Zalo\/WhatsApp: +84-987 056 271<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Cù Hoàng Kiếm (Mr. Kevin)<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n","content":"","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/PT%20calibration\/Pressure-Transmitter-Calibration%203.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/PT%20calibration\/Pressure-Transmitter-Calibration%203.jpg","tags":"Pressure switch calibration,Hiệu chuẩn công tắc mức áp suất,Dịch vụ hiệu chuẩn công tắc mức áp suất,Hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Dịch vụ hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Hiệu chuẩn đồng hồ áp suất,Hiệu chuẩn áp kế,Hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo, Dịch vụ hiệu chuẩn áp kế lò xo,Kiểm định áp kế lò xo,Kiểm định áp kế hiện số,Kiểm định áp kế chân không,Dịch vụ kiểm định áp kế lò xo,Dịch vụ kiểm định áp kế hiện số, Dịch vụ kiểm định áp kế chân không,Kiểm định áp kế kiểu lò xo,Kiểm định chân không kế kiểu lò xo, Hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Dịch vụ hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Hiệu chuẩn đồng hồ áp suất,Hiệu chuẩn áp kế,Hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo, Pressure gauge calibration,Differential pressure gauge calibration,Vaccum gauge calibration,","count_view":0,"seo_name":"pressure-switch-calibration","date_update":0,"date_created_format":"1719653014","meta_title":"Pressure switch calibration","meta_desc":"Pressure switch calibration","meta_keyword":"Pressure switch calibration,Hiệu chuẩn công tắc mức áp suất,Dịch vụ hiệu chuẩn công tắc mức áp suất,Hiệu chuẩn thiết bị đo áp suất,Hiệu chuẩn bộ chuyển đổi áp suất,Hiệu chuẩn pressure transmitter, Hiệu chuẩn thiết bị đo chênh áp, Hiệu chuẩn công tắc áp su","price":false,"price_final":false,"icon_svg":"","qr_code":"https:\/\/www.tkld-technical.com.vn\/pressure-switch-calibration.html"},{"id":50418,"name":"Temperature switch calibration","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Phone\/Zalo\/WhatsApp: +84-987 056 271<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Cù Hoàng Kiếm (Mr. Kevin)<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n","content":"","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/PG%20calibration\/temp%20transmiter%20calibration.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/PG%20calibration\/temp%20transmiter%20calibration.jpg","tags":"Temperature switch calibration,Hiệu chuẩn công tắc mức nhiệt độ,Dịch vụ hiệu chuẩn công tắc mức nhiệt độ,Hiệu chuẩn thiết bị đo nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ hiện kim,Hiệu chuẩn đồng hồ nhiệt độ hiện số,Hiệu chuẩn đồng hồ nhiệt độ theo ISO 17025, Hiệu chuẩn bộ chuyển đổi nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ Pt100,Hiệu chuẩn cảm biến đo nhiệt độ TC Type K,Hiệu chuẩn cảm biến đo nhiệt độ TC Type J, Temperature Indicator calibration,Temperature gauge calibration,Temperature transmitter calibration,Temperature Indicator calibration as per ISO 17025,Temperature gauge calibrationas per ISO 17025,Temperature transmitter calibrationas per ISO 17025,Instrument caibration as per ISO 17025,Hiệu chuẩn thiết bị đo nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ hiện kim,Hiệu chuẩn đồng hồ nhiệt độ hiện số,Hiệu chuẩn đồng hồ nhiệt độ theo ISO 17025, Hiệu chuẩn bộ chuyển đổi nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ Pt100,Hiệu chuẩn cảm biến đo nhiệt độ TC Type K,Hiệu chuẩn cảm biến đo nhiệt độ TC Type J, Temperature Indicator calibration,Temperature gauge calibration,Temperature transmitter calibration,Temperature Indicator calibration as per ISO 17025,Temperature gauge calibrationas per ISO 17025,Temperature transmitter calibrationas per ISO 17025,Instrument caibration as per ISO 17025,","count_view":0,"seo_name":"temperature-switch-calibration","date_update":0,"date_created_format":"1719652818","meta_title":"Temperature switch calibration","meta_desc":"Temperature switch calibration","meta_keyword":"Temperature switch calibration,Hiệu chuẩn công tắc mức nhiệt độ,Dịch vụ hiệu chuẩn công tắc mức nhiệt độ,Temperature switch calibration,Hiệu chuẩn thiết bị đo nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ hiện kim,Hiệu chuẩn đồng hồ nhi","price":false,"price_final":false,"icon_svg":"","qr_code":"https:\/\/www.tkld-technical.com.vn\/temperature-switch-calibration.html"},{"id":50399,"name":"Temperature transmitter calibration","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Phone\/Zalo\/WhatsApp: +84-987 056 271<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Cù Hoàng Kiếm (Mr. Kevin)<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n","content":"","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/PG%20calibration\/temp%20transmiter%20calibration.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/PG%20calibration\/temp%20transmiter%20calibration.jpg","tags":"Hiệu chuẩn thiết bị đo nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ hiện kim,Hiệu chuẩn đồng hồ nhiệt độ hiện số,Hiệu chuẩn đồng hồ nhiệt độ theo ISO 17025, Hiệu chuẩn bộ chuyển đổi nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ Pt100,Hiệu chuẩn cảm biến đo nhiệt độ TC Type K,Hiệu chuẩn cảm biến đo nhiệt độ TC Type J, Temperature Indicator calibration,Temperature gauge calibration,Temperature transmitter calibration,Temperature Indicator calibration as per ISO 17025,Temperature gauge calibrationas per ISO 17025,Temperature transmitter calibrationas per ISO 17025,Instrument caibration as per ISO 17025,Hiệu chuẩn thiết bị đo nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ hiện kim,Hiệu chuẩn đồng hồ nhiệt độ hiện số,Hiệu chuẩn đồng hồ nhiệt độ theo ISO 17025, Hiệu chuẩn bộ chuyển đổi nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ Pt100,Hiệu chuẩn cảm biến đo nhiệt độ TC Type K,Hiệu chuẩn cảm biến đo nhiệt độ TC Type J, Temperature Indicator calibration,Temperature gauge calibration,Temperature transmitter calibration,Temperature Indicator calibration as per ISO 17025,Temperature gauge calibrationas per ISO 17025,Temperature transmitter calibrationas per ISO 17025,Instrument caibration as per ISO 17025,","count_view":0,"seo_name":"temperature-transmitter-calibration","date_update":0,"date_created_format":"1719641626","meta_title":"Temperature transmitter calibration","meta_desc":"Temperature transmitter calibration","meta_keyword":"Hiệu chuẩn thiết bị đo nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ hiện kim,Hiệu chuẩn đồng hồ nhiệt độ hiện số,Hiệu chuẩn đồng hồ nhiệt độ theo ISO 17025, Hiệu chuẩn bộ chuyển đổi nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ,Hiệu chuẩn c","price":false,"price_final":false,"icon_svg":"","qr_code":"https:\/\/www.tkld-technical.com.vn\/temperature-transmitter-calibration.html"},{"id":50398,"name":"Temperature gauge calibration","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Phone\/Zalo\/WhatsApp: +84-987 056 271<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Cù Hoàng Kiếm (Mr. Kevin)<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n","content":"","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/PG%20calibration\/Temp%20gauge%20calibration.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/PG%20calibration\/Temp%20gauge%20calibration.jpg","tags":"Hiệu chuẩn thiết bị đo nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ hiện kim,Hiệu chuẩn đồng hồ nhiệt độ hiện số,Hiệu chuẩn đồng hồ nhiệt độ theo ISO 17025, Hiệu chuẩn bộ chuyển đổi nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ Pt100,Hiệu chuẩn cảm biến đo nhiệt độ TC Type K,Hiệu chuẩn cảm biến đo nhiệt độ TC Type J, Temperature Indicator calibration,Temperature gauge calibration,Temperature transmitter calibration,Temperature Indicator calibration as per ISO 17025,Temperature gauge calibrationas per ISO 17025,Temperature transmitter calibrationas per ISO 17025,Instrument caibration as per ISO 17025,","count_view":0,"seo_name":"temperature-gauge-calibration","date_update":0,"date_created_format":"1719641541","meta_title":"Temperature gauge calibration","meta_desc":"Temperature gauge calibration","meta_keyword":"Hiệu chuẩn thiết bị đo nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ,Hiệu chuẩn đồng hồ nhiệt độ hiện kim,Hiệu chuẩn đồng hồ nhiệt độ hiện số,Hiệu chuẩn đồng hồ nhiệt độ theo ISO 17025, Hiệu chuẩn bộ chuyển đổi nhiệt độ,Hiệu chuẩn cảm biến đo nhiệt độ,Hiệu chuẩn c","price":false,"price_final":false,"icon_svg":"","qr_code":"https:\/\/www.tkld-technical.com.vn\/temperature-gauge-calibration.html"},{"id":50397,"name":"Pressure transmitter calibration","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Phone\/Zalo\/WhatsApp: +84-987 056 271<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Cù Hoàng Kiếm (Mr. Kevin)<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n","content":"","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/PT%20calibration\/Pressure-Transmitter-Calibration%203.jpg","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/PT%20calibration\/Pressure-Transmitter-Calibration%203.jpg","tags":"Hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Dịch vụ hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Hiệu chuẩn đồng hồ áp suất,Hiệu chuẩn áp kế,Hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo, Dịch vụ hiệu chuẩn áp kế lò xo,Kiểm định áp kế lò xo,Kiểm định áp kế hiện số,Kiểm định áp kế chân không,Dịch vụ kiểm định áp kế lò xo,Dịch vụ kiểm định áp kế hiện số, Dịch vụ kiểm định áp kế chân không,Kiểm định áp kế kiểu lò xo,Kiểm định chân không kế kiểu lò xo, Hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Dịch vụ hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Hiệu chuẩn đồng hồ áp suất,Hiệu chuẩn áp kế,Hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo, Pressure gauge calibration,Differential pressure gauge calibration,Vaccum gauge calibration,","count_view":0,"seo_name":"pressure-transmitter-calibration","date_update":0,"date_created_format":"1719641400","meta_title":"Pressure transmitter calibration","meta_desc":"Pressure transmitter calibration","meta_keyword":"Hiệu chuẩn thiết bị đo áp suất,Hiệu chuẩn bộ chuyển đổi áp suất,Hiệu chuẩn pressure transmitter, Hiệu chuẩn thiết bị đo chênh áp, Hiệu chuẩn công tắc áp suất, Hiệu Hiệu chuẩn thiết bị đo áp suất theo tiêu chuẩn ISO 17025,Hiệu chuẩn bộ chuyển đổi áp suất ","price":false,"price_final":false,"icon_svg":"","qr_code":"https:\/\/www.tkld-technical.com.vn\/pressure-transmitter-calibration.html"},{"id":50396,"name":"Pressure gauge and vaccum gauge calibration","desc":"<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Phone\/Zalo\/WhatsApp: +84-987 056 271<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Cù Hoàng Kiếm (Mr. Kevin)<\/span><\/span><\/p>\n\n<p><span style=\"font-family:Times New Roman,Times,serif;\"><span style=\"font-size:16px;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n","content":"","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/PG%20calibration\/Calibration-of-Pressure-Gauge%202.png","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/PG%20calibration\/Calibration-of-Pressure-Gauge%202.png","tags":"Hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Dịch vụ hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Hiệu chuẩn đồng hồ áp suất,Hiệu chuẩn áp kế,Hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo, Dịch vụ hiệu chuẩn áp kế lò xo,Kiểm định áp kế lò xo,Kiểm định áp kế hiện số,Kiểm định áp kế chân không,Dịch vụ kiểm định áp kế lò xo,Dịch vụ kiểm định áp kế hiện số, Dịch vụ kiểm định áp kế chân không,Kiểm định áp kế kiểu lò xo,Kiểm định chân không kế kiểu lò xo, Hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Dịch vụ hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Hiệu chuẩn đồng hồ áp suất,Hiệu chuẩn áp kế,Hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo, Pressure gauge calibration,Differential pressure gauge calibration,Vaccum gauge calibration,","count_view":0,"seo_name":"pressure-gauge-and-vaccum-gauge-calibration","date_update":0,"date_created_format":"1719640449","meta_title":"Pressure gauge and vaccum gauge calibration","meta_desc":"Pressure gauge and vaccum gauge calibration","meta_keyword":"Hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Dịch vụ hiệu chuẩn thiết bị đo áp suất theo ISO 17025,Hiệu chuẩn đồng hồ áp suất,Hiệu chuẩn áp kế,Hiệu chuẩn áp kế lò xo,Dịch vụ hiệu chuẩn áp kế lò xo, Dịch vụ hiệu chuẩn áp kế lò xo,Kiểm định áp kế lò xo,Kiể","price":false,"price_final":false,"icon_svg":"","qr_code":"https:\/\/www.tkld-technical.com.vn\/pressure-gauge-and-vaccum-gauge-calibration.html"},{"id":41456,"name":"Control valve maintenance & calibration services","desc":"<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Nếu quý khách cần yêu cầu chào giá hoặc tư vấn kỹ thuật vui lòng liên hệ:<\/span><\/span><\/p>\n\n<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\"><strong>CÔNG TY TNHH DỊCH VỤ KỸ THUẬT TKLD<\/strong><\/span><\/span><\/p>\n\n<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Phone\/Zalo\/WhatsApp: +84-987 056 271<\/span><\/span><\/p>\n\n<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Cù Hoàng Kiếm (Mr. Kevin)<\/span><\/span><\/p>\n\n<p><span style=\"font-size:14px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Email: info@tkld.com.vn<\/span><\/span><\/p>\n","content":"<p><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Control valve maintenance & calibration services<\/span><\/span><\/p>\n\n<ul>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Specialist <b>Control Valve Servicing<\/b> by TKLD Company for all makes\/brands – servicing, overhaul, supply of spare parts, testing and calibration<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Test standards used : ANSI B16.104\/VDI\/VDE 2174 (Seat leak & Bubble test\/ API 598\/6D<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Overhaul, testing and commissioning of Level Instruments<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Supply of Diagnostic Instruments<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Full Diagnostics monitoring and testing services<\/span><\/span><\/li>\n\t<li><span style=\"font-size:16px;\"><span style=\"font-family:Times New Roman,Times,serif;\">Valvelinks program – for quick assembles and deliveries<\/span><\/span><\/li>\n<\/ul>\n\n<p><img src=\"\/datafiles\/40367\/upload\/images\/TKLD%20DVC6200%20Calibration%20(1).jpg\" style=\"width: 800px; height: 1067px;\" \/><\/p>\n","image_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/images\/Control%20Valve%20Services\/Serven%20Glocon%2012%20inch%20Control%20valve.JPG","image_thumb_url":"https:\/\/www.tkld-technical.com.vn\/datafiles\/40367\/upload\/thumb_images\/Control%20Valve%20Services\/Serven%20Glocon%2012%20inch%20Control%20valve.JPG","tags":"Control valve maintenance services,Control valve calibration services,Control valve maintenance and calibration services,Ball Valve Hydrostatic test, Ball Valve Leak test, Butterfly Control Valve Maintenance Services, Butterfly Valve Ball Valve Hydrostatic test, Check Valve Hydrostatic test, Check Valve Leak test, Control Valve Cablibration, Control Valve Calibration, Control valve calibration service, Control Valve Calibration Services, Control valve commissioning and testing, Control Valve Hydrostatic test, Control Valve Inspection, Control Valve Inspection and Calibration, Control valve inspection and testing, Control Valve Inspection Service, Control Valve Maintenance and Testing, Control Valve Maintenance Services, Control valve maintenance training, Control Valve Overhaul, Control valve overhaul training, Control valve pre-commissioning, Control Valve Repair, Control Valve Repair Serivce, Control Valve Seat Leak test, Control Valve Services, Control Valve Testing, Control Valve Testing Service, Fucntion test control valves, Gate Valve Hydrostatic test, Gate Valve Leak test, Gate Valve Repair Serivce, Gia công mặt làm kín van, Globe Control Valve Maintenance Services, Globe Valve Hydrostatic test, Globe Valve Leak test, Hydrostatic test as per API 598, Hydrostatic test as per API 6D, Manual valve hydrostatic test, Manual valve leak test, Manual Valve Repair Serivce, Manual valve testing, On-Off Valve Hydrostatic test, On-Off Valve Repair Serivce, On-Off Valve Seat Leak test, Overhaul Control Valves, Pneumatic actuator overhaul, Pneumatic actuator testing, Positioner repair, Pressure Safety Valve Calibration Service, Pressure Safety Valve Maintenance, Pressure Safety Valve Overhaul, Pressure Safety Valve Repair Serivce, Pressure Safety Valve Testing, Pressure Safety Valve Verification Service, PSV repair, PSV testing, PSV Verification, Repair control valves, Rotork actuator maintenance service, Samson control valves, Seat Leak test as per API 598, Seat Leak test as per FCI 70-2, Seat Leakage Test as per API 527,Valve calibration Service, valve raise face lapping, valve raise face repair, Valve Services, Valve Surface lapping","count_view":0,"seo_name":"control-valve-maintenance-calibration-services","date_update":0,"date_created_format":"1729947169","meta_title":"Control valve maintenance & calibration services","meta_desc":"Control valve maintenance & calibration services","meta_keyword":"Control valve maintenance services,Control valve calibration services,Control valve maintenance and calibration services,Ball Valve Hydrostatic test, Ball Valve Leak test, Bảo dưỡng sửa chữa van điều khiển, bảo dưỡng thiết bị, Bảo dưỡng van, bảo trì, bảo ","price":false,"price_final":false,"icon_svg":"","qr_code":"https:\/\/www.tkld-technical.com.vn\/control-valve-maintenance-calibration-services.html"}]},"widget_6796089":{"content_data":{"content":"Thống kê truy cập"}},"widget_6796064":{"content_data":{"content":"Thiết Kế Website bởi P.A Việt Nam"}},"category_desc":"","title_page":"News"}